Abstract
The impedance of a capacitively coupled radio fre- quency discharge in a tubular fluorescent lamp filled with neon and mercury is measured. The stray impedances in the electrical network are determined using a new method that requires no ex- tra instruments. The reflection of power is used to determine the stray impedances. Making use of a simple discharge impedance model, the electron density in the lamp is estimated.

This publication has 17 references indexed in Scilit: