Can Wound Desiccation Be Averted During Cardiac Surgery? An Experimental Study
Authors:
- Mikael PerssonMPMikael Persson
- Jan van der LindenJLJan van der Linden
- 1 February 2005
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 100 (2) , 315-320
Abstract
During cardiac surgery the wound is exposed to desiccation, especially as a result of operating room ventilation and the insufflation of dry carbon dioxide (CO(2)) for de-airing. We compared the gas humidity and desiccation rates in an in vitro model of a cardiothoracic wound during these conditions and during insufflation of humidified CO(2). To assess the influence of flow velocity, CO(2) was insufflated at 10 L/min via two devices, a standard open-ended tube and a low-velocity gas diffuser. The treatment arms were compared with a control without insufflation. When insufflated via the open-ended tube the humidity in the model was almost equal to the control, both with dry and humidified CO(2). However, the total desiccation rate was more rapid than the control (P < 0.001), especially in the area exposed to the gas jet where the desiccation rate was three times more rapid (P < 0.001). With the gas diffuser, dry CO(2) caused almost zero humidity and a desiccation rate that was almost equal to the control. Humidified CO(2) increased humidity in comparison with the control (P < 0.001) and decreased the desiccation rate by >90% (P < 0.001). Humidified CO(2) may be used to avert desiccation of the cardiothoracic wound. The humidified gas is effective only when delivered via a low-velocity outlet device.Keywords
This publication has 21 references indexed in Scilit:
- Effect of CO 2 Insufflation on the Number and Behavior of Air Microemboli in Open-Heart SurgeryCirculation, 2004
- De-airing of a cardiothoracic wound cavity model with carbon dioxide:theory and comparison of a gas diffuser with conventional tubesJournal of Cardiothoracic and Vascular Anesthesia, 2003
- Intermittent or Continuous Carbon Dioxide Insufflation for De-Airing of the Cardiothoracic Wound Cavity? An Experimental Study with a New Gas-DiffuserAnesthesia & Analgesia, 2003
- Coronary endothelial damage during off-pump CABG related to coronary-clamping and gas insufflationEuropean Journal of Cardio-Thoracic Surgery, 2001
- Laparoscopy and Tribology: The Effect of Laparoscopic Gas on Peritoneal FluidThe Journal of the American Association of Gynecologic Laparoscopists, 2001
- Carbon dioxide field flooding techniques for open heart surgery: monitoring and minimizing potential adverse effectsPerfusion, 2000
- A randomized controlled trial to determine the effects of humidified carbon dioxide insufflation during thoracoscopySurgical Endoscopy, 1999
- Prevention of Postoperative Pericardial Adhesions Using Tissue-Protective SolutionsJournal of Surgical Research, 1997
- Perioperative histologic and ultrastructural changes in the pericardium and adhesionsThe Annals of Thoracic Surgery, 1994
- Carbon dioxide in the prevention of air embolism during open-heart surgeryThorax, 1968