Interrelationships between electrical properties and microstructure of human trabecular bone
Authors:
- J SierpowskaJSJ Sierpowska
- M A HakulinenMHM A Hakulinen
- J TöyräsJTJ Töyräs
- J S DayJDJ S Day
- H WeinansHWH Weinans
- I KivirantaIKI Kiviranta
- J S JurvelinJJJ S Jurvelin
- R LappalainenRLR Lappalainen
- 2 October 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (20) , 5289-5303
Abstract
Microstructural changes, such as reduction of trabecular thickness and number, are characteristic signs of osteoporosis leading to diminished bone strength. Electrical and dielectric parameters might provide diagnostically valuable information on trabecular bone microstructure not extractable from bone mineral density measurements. In this study, structural properties of human trabecular bone samples (n=26) harvested from the distal femur and proximal tibia were investigated using the computed microtomography (microCT) technique. Quantitative parameters, e.g. structural model index (SMI) or trabecular bone volume fraction (BV/TV), were calculated. In addition, the samples were examined electrically over a wide frequency range (50 Hz-5 MHz) using a two-electrode impedance spectroscopy set-up. Relative permittivity, loss factor, conductivity, phase angle, specific impedance and dissipation factor were determined. Significant linear correlations were obtained between the dissipation factor and BV/TV or SMI (|r| 0.70, p<0.01, n=26). Principal component analyses, conducted on electrical and structural parameters, revealed that the high frequency principal component of the dissipation factor was significantly related to SMI (r=0.72, p<0.01, n=26). The linear combination of high and low frequency relative permittivity predicted 73% of the variation in BV/TV. To conclude, electrical and dielectric parameters of trabecular bone, especially relative permittivity and dissipation factor, were significantly and specifically related to a trabecular microstructure as characterized with microCT. The data gathered in this study constitute a useful basis for theoretical and experimental work towards the development of impedance spectroscopy techniques for detection of bone quality in vitro or in special cases of open surgery.Keywords
This publication has 39 references indexed in Scilit:
- Numerical simulations of dielectric properties of composite material with periodic structureJournal of Electrostatics, 2005
- Prediction of mechanical properties of human trabecular bone by electrical measurementsPhysiological Measurement, 2005
- Electrical and dielectric properties of bovine trabecular bone relationships with mechanical properties and mineral densityPhysics in Medicine & Biology, 2003
- A new method for the model‐independent assessment of thickness in three‐dimensional imagesJournal of Microscopy, 1997
- Quantification of Bone Microarchitecture with the Structure Model IndexComputer Methods in Biomechanics and Biomedical Engineering, 1997
- The dielectric properties of biological tissues: I. Literature surveyPhysics in Medicine & Biology, 1996
- Structure model index — A new method to describe remodeling of trabecular boneBone, 1996
- Comparison of the electrical and dielectric behavior of wet human cortical and cancellous bone tissue from the distal tibiaJournal of Orthopaedic Research, 1995
- The effect of different storage methods on the mechanical properties of trabecular boneJournal of Biomechanics, 1993
- Effect of Moisture on the Electrical Properties of BoneJournal of the Electrochemical Society, 1976