Towards a portable human gait analysis & monitoring system
Authors:
- Poorna Talkad SukumarPSPoorna Talkad Sukumar
- 1 May 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 174-180
Abstract
Human Gait analysis is useful in many cases, such as, detecting the underlying cause of an abnormal gait, rehabilitation of subjects suffering from motor related diseases such as Parkinson's disease or Cerebral Palsy, improving the athletic performance of sports person etc. However, gait analysis has seen limited usage, especially in developing countries, because of the high cost involved in setting up a gait laboratory. We present a portable gait analysis system using Inertial Measurement Unit (IMU) sensors to collect movement data and a Smart-phone to process it. IMU sensors has gained significant popularity in the last few years as viable option for gait analysis because its low cost, small size and ease of use. Using the accelerometer and gyroscope data from 3 EXL-S3 IMU sensors (on thigh, shank and foot), we measure kinematic angles in the sagittal plane and detect Heel Strike (HT) and Toe Off (TO) events using methods based on [11] and [4] respectively. To measure the accuracy of our system, we compare it with an Optical Gait Analysis system, which is the current gold standard for gait analysis 1 . We measure the gait parameters for 3 healthy individuals belonging to different age group and achieve an RMSE of 4.739° ± 1.961°, 3.7° ± 3.02° and 4.12° ± 1.21° for Knee Flexion Extension, Ankle Dorsi Flexion respectively and Hip Flexion Extension respectively. We measure the Heel Strike and Toe Off using shank and foot mounted sensor independently. 34.5 ± 28.3 ms and 27.5 ± 32.8 ms is the RMSE for HT calculated by shank and foot sensor w.r.t. optical system respectively. The RMSE for Toe Off is 36.2 ± 36.8 ms and 37.5 ± 35.9 ms for shank and foot sensor w.r.t. optical system respectively.Keywords
This publication has 14 references indexed in Scilit:
- Validation of Inter-Subject Training for Hidden Markov Models Applied to Gait Phase Detection in Children with Cerebral PalsySensors, 2015
- Drift Removal for Improving the Accuracy of Gait Parameters Using Wearable Sensor SystemsSensors, 2014
- MEMS IMU/ZUPT Based Cubature Kalman Filter Applied to Pedestrian Navigation System2014
- A Wearable System for Gait Training in Subjects with Parkinson’s DiseaseSensors, 2014
- Gait analysis in children with cerebral palsy via inertial and magnetic sensorsMedical & Biological Engineering & Computing, 2012
- Joint axis and position estimation from inertial measurement data by exploiting kinematic constraints2012
- ‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensorsMedical & Biological Engineering & Computing, 2009
- Magnetic distortion in motion labs, implications for validating inertial magnetic sensorsGait & Posture, 2009
- Quantification of human motion: gait analysis—benefits and limitations to its application to clinical problemsJournal of Biomechanics, 2004
- The evolution of clinical gait analysisGait & Posture, 2002