Fetal MEG Redistribution by Projection Operators
Authors:
- J. VrbaJVJ. Vrba
- C.L. LoweryCLC.L. Lowery
- H. EswaranHEH. Eswaran
- J.D. WilsonJWJ.D. Wilson
- P. MurphyPMP. Murphy
- H. PreiblHPH. Preibl
- H. PreisslHPH. Preissl
- 21 June 2004
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 51 (7) , 1207-1218
Abstract
The fetal magnetoencephalogram (fMEG) is measured in the presence of large interference from the maternal and fetal magnetocardiograms. This interference can be efficiently attenuated by orthogonal projection of the corresponding spatial vectors. However, the projection operators redistribute the fMEG signal among sensors. Although redistribution can be readily accounted for in the forward solution, visual interpretation of the fMEG signal topography is made difficult. We have devised a general, model-independent method for correction of the redistribution effect that utilizes the assumption that we know in which channels the fMEG should be negligible (such channels are distant from the known fetal head position). In a simplified case where the fMEG can be explained by equivalent current dipoles, the correction can also be obtained from fitting the dipoles to the fMEG signal. The corrected fMEG signal topography then corresponds to the dipole forward solution, but without orthogonal projection. We illustrate the redistribution correction on an example of experimentally measured flash evoked fMEG.Keywords
This publication has 32 references indexed in Scilit:
- Human fetal brain imaging by magnetoencephalography: verification of fetal brain signals by comparison with fetal brain modelsNeuroImage, 2004
- A resampling method for estimating the signal subspace of spatio-temporal eeg/meg dataIEEE Transactions on Biomedical Engineering, 2003
- Short-term serial magnetoencephalography recordings offetal auditory evoked responsesNeuroscience Letters, 2002
- Detection of fetal auditory evoked responses by means of magnetoencephalographyBrain Research, 2001
- Eigenvector based spatial filtering of fetal biomagnetic signalsJournal of Perinatal Medicine, 2001
- Recording of Temporal-Spatial Biomagnetic Signals over the whole Maternal Abdomen with SARA - Auditory Fetal Brain ResponsesBiomedical Engineering / Biomedizinische Technik, 2001
- Conversion of magnetocardiographic recordings between two different multichannel SQUID devicesIEEE Transactions on Biomedical Engineering, 2000
- Functional localization based on measurements with a whole-head magnetometer systemBrain Topography, 1995
- Methods for separating temporally overlapping sources of neuroelectric dataBrain Topography, 1988
- Principal components analysis for source localization of VEPs in manVision Research, 1987