Comparison of Stability of Fracture Segments in Mandible Fracture Treated with Different Designs of Mini-Plates Using FEM Analysis
- 16 April 2013
- journal article
- research article
- Published by Springer Nature in Journal of Maxillofacial and Oral Surgery
- Vol. 13 (3) , 310-319
Abstract
Aim To compare the displacement gap of mandible fracture segments treated with different designs of mini-plates under various loading conditions. Materials and Methods Fracture in the body of mandible was bridged with 15 different designs and configuration of titanium mini-plates. Bite forces were applied at 3 locations, ipsilateral fractured side, contra lateral side and incisor site. 3D finite element methods (FEM) model of mandible was generated using 10 nodal tetrahedral elements. A commercial FE solver was used to solve bone inter fragmentary displacement during loading. Results Superior position of mini-plates produced better stability than inferior position. Positive bending moments can be reduced by larger plate in lower border in 2 plate system. Results of X mini-plate are comparable to 2 plate configuration. If length of middle portion of plate increased, stability decreased. Number of screws did not affect fracture stability. Conclusion Finite element methods analysis is used to determine the gap between mandible fragments which is otherwise impossible to measure clinically. The results obtained from this study offered us a choice of mini-plate design and configuration for clinical application.Keywords
This publication has 26 references indexed in Scilit:
- Evaluation of different miniplates in fixation of fractured human mandible with the finite element methodOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2007
- Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: A 3D finite element analysisMedical Engineering & Physics, 2005
- New innovations in craniomaxillofacial fixation: the 2.0 lock system.The Keio Journal of Medicine, 2003
- A three-dimensional study of loads across the fracture for different fracture sites of the mandibleBritish Journal of Oral and Maxillofacial Surgery, 1996
- Bite forces in patients treated for mandibular angle fractures: Implications for fixation recommendationsJournal of Oral and Maxillofacial Surgery, 1994
- Testing biomechanical strength of repairs for the mandibular angle fractureThe Laryngoscope, 1994
- A comparison of three finite element models of an edentulous mandible provided with implantsJournal of Oral Rehabilitation, 1993
- Modeling the biomechanics of the mandible: A three-dimensional finite element studyJournal of Biomechanics, 1992
- Infection after rigid internal fixation of mandibular fractures: A clinical and radiologic studyJournal of Oral and Maxillofacial Surgery, 1991
- Osteosynthesis with miniaturized screwed plates in maxillo-facial surgeryJournal of Maxillofacial Surgery, 1973