Differences in the diagnostic value between fiberoptic and high definition laryngoscopy for the characterisation of pharyngeal and laryngeal lesions: A multi‐observer paired analysis of videos
Authors:
- Constanze ScholmanCSConstanze Scholman
- Jeroen M. WestraJWJeroen M. Westra
- Manon A. ZwakenbergMZManon A. Zwakenberg
- Frederik G. DikkersFDFrederik G. Dikkers
- Gyorgy B. HalmosGyorgy B. Halmos
- Jan WedmanJWJan Wedman
- Jan E. WachtersJWJan E. Wachters
- Bernard F.A.M. van der LaanBLBernard F.A.M. van der Laan
- Boudewijn E.C. PlaatBPBoudewijn E.C. Plaat
Open Access
- 20 November 2019
- journal article
- research article
- Published by Wiley in Clinical Otolaryngology
- Vol. 45 (1) , 119-125
Abstract
Objectives: High definition laryngoscopy (HDL) could lead to better interpretation of the pharyngeal and laryngeal mucosa than regularly used fiberoptic laryngoscopy (FOL). The primary aim of this study is to quantify the diagnostic advantage of HDL over FOL in detecting mucosal anomalies in general, in differentiating malignant from benign lesions and in predicting specific histological entities. The secondary aim is to analyse image quality of both laryngoscopes.Design: Retrospective paired analysis with multiple observers evaluating endoscopic videos simulating daily clinical practice.Setting: A tertiary referral hospital.Participants: In 36 patients, both FOL and HDL videos were obtained. Six observers were provided with additional clinical information, and 36 FOL and HDL videos were evaluated in a randomised order.Main outcome measures: Sensitivity, specificity, positive and negative predictive value and diagnostic accuracy of observers using both flexible laryngoscopes were calculated for detection of mucosal lesions in general and uncovering malignant lesions. Sensitivities were calculated for prediction of specific histological entities. Image quality (scale 1‐10) was assessed for both flexible laryngoscopes.Results: HDL reached higher sensitivity compared to FOL for detection of mucosal abnormalities in general (96.0% vs 90.4%; P = .03), differentiating malignant from benign lesions (91.7% vs 79.8%; P = .03) and prediction of specific histological entities (59.7% vs 47.2%; P < .01). Image quality was judged better with HDL in comparison with FOL (mean: 8.4 vs 5.4, P < .01).Conclusions: HDL is superior to FOL in detecting mucosal anomalies in general, malignancies and specific histological entities. Image quality is considered as superior using HDL compared to FOL.Keywords
This publication has 25 references indexed in Scilit:
- Adoption of Video Laryngoscopy in Massachusetts Emergency DepartmentsThe Journal of Emergency Medicine, 2012
- Voluntary Medical Male Circumcision: A Framework Analysis of Policy and Program Implementation in Eastern and Southern AfricaPLOS Medicine, 2011
- High-resolution and high-magnification endoscopesGastrointestinal Endoscopy, 2009
- Radiologic Evaluation of Larynx CancerOtolaryngologic Clinics of North America, 2008
- A full digital, high definition video system (1080i) for laryngoscopy and stroboscopyThe Journal of Laryngology & Otology, 2007
- Automatic Adaptive Enhancement for Images Obtained With Fiberscopic EndoscopesIEEE Transactions on Biomedical Engineering, 2006
- Laryngeal cancer patients: Analysis of patient delay at different tumor stagesHead & Neck, 2005
- Squamous cell carcinoma in situ at oropharyngeal and hypopharyngeal mucosal sitesCancer, 2004
- Office videofiberoptic laryngoscopyThe Laryngoscope, 1984
- A Flexible Fibrescope, using Static ScanningNature, 1954