Interlocking Nailing Versus Interlocking Plating in Intra-articular Calcaneal Fractures
- 20 July 2016
- journal article
- research article
- Published by SAGE Publications in Foot & Ankle International
- Vol. 37 (8) , 891-897
Abstract
Open reduction and internal fixation with a plate is deemed to represent the gold standard of surgical treatment for displaced intra-articular calcaneal fractures. Standard plate fixation is usually placed through an extended lateral approach with high risk for wound complications. Minimally invasive techniques might avoid wound complications but provide limited construct stability. Therefore, 2 different types of locking nails were developed to allow for minimally invasive technique with sufficient stability. The aim of this study was to quantify primary stability of minimally invasive calcaneal interlocking nail systems in comparison to a variable-angle interlocking plate. After quantitative CT analysis, a standardized Sanders type IIB fracture model was created in 21 fresh-frozen cadavers. For osteosynthesis, 2 different interlocking nail systems (C-Nail; Medin, Nov. Město n. Moravě, Czech Republic; Calcanail; FH Orthopedics SAS; Heimsbrunn, France) as well as a polyaxial interlocking plate (Rimbus; Intercus GmbH; Rudolstadt, Germany) were used. Biomechanical testing consisted of a dynamic load sequence (preload 20 N, 1000 N up to 2500 N, stepwise increase of 100 N every 100 cycles, 0.5 mm/s) and a load to failure sequence (max. load 5000 N, 0.5 mm/s). Interfragmentary movement was detected via a 3-D optical measurement system. Boehler angle was measured after osteosynthesis and after failure occurred. No significant difference regarding load to failure, stiffness, Boehler angle, or interfragmentary motion was found between the different fixation systems. A significant difference was found with the dynamic failure testing sequence where 87.5% of the Calcanail implants failed in contrast to 14% of the C-Nail group (P < .01) and 66% of the Rimbus plate. The highest load to failure was observed for the C-Nail. Boehler angle showed physiologic range with all implants before and after the biomechanical tests. Both minimally invasive interlocking nail systems displayed a high primary stability that was not inferior to an interlocking plate. Based on our results, both interlocking nails appear to represent a viable option for treating displaced intra-articular calcaneal fractures.Keywords
This publication has 21 references indexed in Scilit:
- Reduction and internal fixation of displaced intra-articular calcaneal fractures with a locking nail: a prospective study of sixty nine casesInternational Orthopaedics, 2015
- Fractures of the Calcaneus: Current Treatment StrategiesActa Chirurgiae Orthopaedicae Et Traumatologiae Cechoslovaca, 2014
- Osteosynthese dislozierter intraartikulärer KalkaneusfrakturenOperative Orthopädie und Traumatologie, 2013
- Evaluation of a new optical measuring system for experiments on fractured human mandiblesClinical Oral Investigations, 2011
- The sinus tarsi approach in displaced intra-articular calcaneal fractures: a systematic reviewInternational Orthopaedics, 2011
- A comparison of conventional versus locking plates in intraarticular calcaneus fractures: A biomechanical study in human cadaversClinical Biomechanics, 2007
- Boehler's angle and the critical angle of Gissane are of limited use in diagnosing calcaneus fractures in the EDThe American Journal of Emergency Medicine, 2006
- A Biomechanical Comparison of Locking and Nonlocking Plates for the Fixation of Calcaneal FracturesFoot & Ankle International, 2006
- Displaced Intra-Articular Fractures of the Calcaneus*Journal of Bone and Joint Surgery, 2000
- The mechanism, reduction technique, and results in fractures of the OS calcisBritish Journal of Surgery, 1952