Scanning Electron Microscopy and EDX Spectroscopy of Commercial Swabs Used for COVID-19 Lateral Flow Testing
Open Access
Abstract
The chemical composition of COVID test swabs has not been examined beyond the manufacturer’s datasheets. The unprecedented demand for swabs to conduct rapid lateral flow tests and nucleic acid amplification tests led to mass production, including 3D printing platforms. Manufacturing impurities could be present in the swabs and, if so, could pose a risk to human health. We used scanning electron microscopy and energy dispersive X-ray (EDX) spectroscopy to examine the ultrastructure of seven assorted brands of COVID test swabs and to identify and quantify their chemical elements. We detected eight unexpected elements, including transition metals, such as titanium and zirconium, the metalloid silicon, as well as post-transition metals aluminium and gallium, and the non-metal elements sulphur and fluorine. Some of the elements were detected as trace amounts, but for others, the amount was close to reported toxicological thresholds for inhalation routes. Experimental studies have shown that the detrimental effects of unexpected chemical elements include moderate to severe inflammatory states in the exposed epithelium as well as proliferative changes. Given the massive testing still being used in the context of the COVID pandemic, we urge caution in continuing to recommend repeated and frequent testing, particularly of healthy, non-symptomatic, individuals.Keywords
All Related Versions
This publication has 79 references indexed in Scilit:
- Toxic Effects of Silica Nanoparticles on Zebrafish Embryos and LarvaePLOS ONE, 2013
- Toxic effects of the interaction of titanium dioxide nanoparticles with chemicals or physical factorsInternational Journal of Nanomedicine, 2013
- Silica-based nanoprobes for biomedical imaging and theranostic applicationsChemical Society Reviews, 2012
- Comparison of Nasopharyngeal and Oropharyngeal Swabs for the Diagnosis of Eight Respiratory Viruses by Real-Time Reverse Transcription-PCR AssaysPLOS ONE, 2011
- The nanosilica hazard: another variable entityParticle and Fibre Toxicology, 2010
- Inhalation exposure to nanosized and fine TiO2 particles inhibits features of allergic asthma in a murine modelParticle and Fibre Toxicology, 2010
- DNA damage and alterations in expression of DNA damage responsive genes induced by TiO2nanoparticles in human hepatoma HepG2 cellsNanotoxicology, 2010
- Comparison of Polyurethane Foam to Nylon Flocked Swabs for Collection of Secretions from the Anterior Nares in Performance of a Rapid Influenza Virus Antigen Test in a Pediatric Emergency DepartmentJournal of Clinical Microbiology, 2010
- Titanium dioxide nanoparticles induce emphysema‐like lung injury in miceThe FASEB Journal, 2006
- Titanium Dioxide: Inhalation Toxicology and EpidemiologyAnnals of Occupational Hygiene, 2005