Microembolism and Catheter Ablation I
Authors:
- 1 February 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 6 (1) , 16-22
Abstract
Background—: Cerebral diffusion-weighted MRI lesions have been observed after catheter ablation of atrial fibrillation. We hypothesized that conditions predisposing to microembolization could be identified using a porcine model of pulmonary vein ablation and an extracorporeal circulation loop. Methods and Results—: Ablations of the pulmonary veins were performed in 18 swine with echo monitoring. The femoral artery and vein were cannulated and an extracorporeal circulation loop with 2 ultrasonic bubble detectors and a 73-μm filter were placed in series. Microemboli and microbubbles were compared between ablation with an irrigated radiofrequency system (Biosense-Webster) and a phased radiofrequency multielectrode system (pulmonary vein ablation catheter [PVAC], Medtronic, Inc, Carlsbad, CA) in unipolar and 3 blended unipolar/bipolar modes. Animal pathology was examined. The size and number of microbubbles observed during ablation ranged from 30 to 180 μm and 0 to 3253 bubbles per ablation. Microbubble volumes with PVAC (29.1 nL) were greater than with irrigated radiofrequency (0.4 nL; P =0.045), and greatest with type II or III microbubbles on transesophageal echocardiography. Ablation with the PVAC showed fewest microbubbles in the unipolar mode ( P =0.012 versus bipolar). The most occurred during bipolar energy delivery with overlap of proximal and distal electrodes (median microbubble volume, 1744 nL; interquartile range, 737–4082 nL; maximum, 19 516 nL). No cerebral MRI lesions were seen, but 2 animals had renal embolization. Conclusions—: Left atrial ablation with irrigated radiofrequency and PVAC catheters in swine is associated with microbubble and microembolus production. Avoiding overlap of electrodes 1 and 10 on PVAC should reduce the microembolic burden associated with this procedure.Keywords
This publication has 21 references indexed in Scilit:
- Incidence of Asymptomatic Intracranial Embolic Events After Pulmonary Vein IsolationJACC, 2011
- MEDAFI-Trial (Micro-embolization during ablation of atrial fibrillation): comparison of pulmonary vein isolation using cryoballoon technique vs. radiofrequency energyEP Europace, 2010
- Incidence and predictors of silent cerebral embolism during pulmonary vein catheter ablation for atrial fibrillationEP Europace, 2009
- Risk of Thromboembolic Events After Percutaneous Left Atrial Radiofrequency Ablation of Atrial FibrillationCirculation, 2006
- Transcranial Doppler Detection of Microembolic Signals During Pulmonary Vein Antrum Isolation: Implications for Titration of Radiofrequency EnergyJournal of Cardiovascular Electrophysiology, 2006
- Increased Intensity of Anticoagulation May Reduce Risk of Thrombus During Atrial Fibrillation Ablation Procedures in Patients with Spontaneous Echo ContrastJournal of Cardiovascular Electrophysiology, 2005
- Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial FibrillationCirculation, 2005
- Phased-Array Intracardiac Echocardiography Monitoring During Pulmonary Vein Isolation in Patients With Atrial FibrillationCirculation, 2003
- Thrombogenicity of radiofrequency ablation procedures: what factors influence thrombin generation?EP Europace, 2001
- Embolic complications after radiofrequency catheter ablationThe American Journal of Cardiology, 1994