Reproducibility and stability of voluntary deep inspiration breath hold and free breath in breast radiotherapy based on real-time 3-dimensional optical surface imaging system
Open Access
- 11 November 2024
- journal article
- research article
- Published by Springer Nature in Radiation Oncology
- Vol. 19 (1) , 1-14
Abstract
The aim of this study was to evaluate the inter-fraction reproducibility and intra-fraction stability of breast radiotherapy using voluntary deep-inspiration breath hold (DIBH) and free breathing (FB) based on an optical surface imaging system (OSIS). Seventeen patients (510 breath-hold sessions) treated using a field-in-field (FiF) technique and twenty patients (600 breath-free sessions) treated with a volume-modulated arc therapy (VMAT) technique were included in this retrospective study. All the patients were positioned with the guidance of CBCT and OSIS, and also monitored with OSIS throughout the whole treatment session. Eight setup variations in three directions were extracted from the treatment reports of OSIS for all sessions and were subsequently manually introduced to treatment plans, resulting in a total of 296 perturbed plans. All perturbed plans were recalculated, and the dose volume histograms (DVH) for the target and organs at risk (OAR) were analyzed. The OSIS and CBCT for both DIBH and FB treatments showed a good agreement of less than 0.30 cm in each direction. The intra-fraction respiratory motion data during DIBH were −0.06 ± 0.07 cm, 0.12 ± 0.15 cm, and 0.12 ± 0.12 cm in the lateral, longitudinal, and vertical directions, respectively; for FB, the respiratory motion data were −0.02 ± 0.12 cm, 0.08 ± 0.18 cm, and 0.14 ± 0.20 cm, respectively. For the target, DIBH plans were more sensitive to setup errors; the mean deviations in D95 for CTV were 39.78 Gy–40.17 Gy for DIBH and 38.46 Gy–40.52 Gy for FB, respectively. For the OARs, the mean deviations of V10, V20, and Dmean to the heart; V5, V20, and Dmean to the ipsilateral lung; and Dmean to the breast were lower for the FB plan compared with the DIBH plan. Based on OSIS, our results indicate that both DIBH and FB can provide good reproducibility in the inter-fractions and stability in the intra-fractions. When the patient respiratory motion is large, the FB technology has greater possibility for the undercoverage of the target volume, while DIBH technology is more likely to result in increases in dose to OARs (the lung, heart, and contralateral breast).Keywords
All Related Versions
Funding Information
- Sichuan Natural Science Foundation Program (2024NSFSC1878)
- Sichuan Cancer Hospital Youth Project (YB2023025, YB2021032)
This publication has 32 references indexed in Scilit:
- A comparative dosimetric study for treating left-sided breast cancer for small breast size using five different radiotherapy techniques: conventional tangential field, filed-in-filed, Tangential-IMRT, Multi-beam IMRT and VMATRadiation Oncology, 2013
- Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Dosimetric comparison of the field-in-field technique and tangential wedged beams for breast irradiationJapanese Journal of Radiology, 2011
- Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death: meta-analysis of individual patient data for 10 801 women in 17 randomised trialsThe Lancet, 2011
- Evaluation of volumetric modulated arc therapy for cranial radiosurgery using multiple noncoplanar arcsMedical Physics, 2011
- Using surface imaging and visual coaching to improve the reproducibility and stability of deep-inspiration breath hold for left-breast-cancer radiotherapyPhysics in Medicine & Biology, 2009
- A Multicenter Randomized Trial of Breast Intensity-Modulated Radiation Therapy to Reduce Acute Radiation DermatitisJournal of Clinical Oncology, 2008
- Randomised trial of standard 2D radiotherapy (RT) versus intensity modulated radiotherapy (IMRT) in patients prescribed breast radiotherapyRadiotherapy and Oncology, 2007
- A simple dose gradient measurement tool to complement the conformity indexJournal of Neurosurgery, 2006
- Evaluation of a standard breast tangent technique: a dose-volume analysis of tangential irradiation using three-dimensional toolsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2000