Potential migration release of volatile compounds from plastic containers destined for food use in microwave ovens
Authors:
- 1 June 2002
- journal article
- research article
- Published by Taylor & Francis in Food Additives & Contaminants
- Vol. 19 (6) , 594-601
Abstract
Several commercially available plastic containers of polycarbonate, polypropylene-copolymer, polypropylene-20% talcum, polypropylene random and styrene-acrylonitrile designed for heating food in microwave ovens were studied. The analytical procedure based on a purge & trap (P&T) GC-MS was optimized. It consisted of heating the materials at 100°C in a P&T system coupled in line with GC-MS equipment. The compounds released from the materials were then identified through their mass spectra. Variables such as the time of purge using helium as the carrier gas in the system, sample temperature, the type of solid trap, the desorption temperature and the time as well as chromatographic separation of all the compounds released from the plastic were optimized. Compounds such as methylbenzene, ethylbenzene, 1-octene, xylene, styrene and 1,4-dichlorobenzene were found in all the containers. Quantitative analysis and potential migrations are reported and discussed.Keywords
This publication has 3 references indexed in Scilit:
- The suitability of alternative fatty food simulants for overall migration testing under both low‐ and high‐temperature test conditionsFood Additives & Contaminants, 1997
- Migration from Food Contact Materials1996
- Identification of potential migrants from samples of dual‐ovenable plasticsFood Additives & Contaminants, 1995