A Thyristor-Based DC Fault Current Limiter With Inductor Inserting–Bypassing Capability
- 1 May 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 7 (3) , 1748-1757
Abstract
DC fault current limiters (FCL) are becoming increasingly important for the prompt DC fault clearance of modular multilevel converter (MMC) based HVDC grid. This paper proposes a hybrid FCL topology, in which the main current limiting circuit is composed of thyristors, capacitors and an inductor. Detailed theoretical analysis of the current limiting processes was carried out to check the electrical stresses. The relationship between the voltage stress and the current limiting time was analyzed, then a design method for the FCL parameters was provided. An effective method for fast bypassing the FCL inductor was proposed to reduce the energy dissipation when fault current is interrupted by a DC Circuit Breaker (DCCB). The dynamic performance of the proposed approach has shown that the proposed FCL can effectively limit the rate of rising of the DC fault current and reduce the energy dissipation.Keywords
Funding Information
- National Natural Science Foundation of China (51607065, 51777072)
This publication has 22 references indexed in Scilit:
- Assembly HVDC Breaker for HVDC Grids With Modular Multilevel ConvertersIEEE Transactions on Power Electronics, 2016
- A DC grid benchmark model for studies of interconnection of power systemsCSEE Journal of Power and Energy Systems, 2015
- Modelling of high power mechanical DC circuit breaker2015
- Bridge-Type Solid-State Fault Current Limiter Based on AC/DC ReactorIEEE Transactions on Power Delivery, 2015
- Identification and Small-Signal Analysis of Interaction Modes in VSC MTDC SystemsIEEE Transactions on Power Delivery, 2015
- Impact of DC Breaker Systems on Multiterminal VSC-HVDC StabilityIEEE Transactions on Power Delivery, 2015
- Technical Assessment of Load Commutation Switch in Hybrid HVDC BreakerIEEE Transactions on Power Electronics, 2014
- Application of Frequency-Partitioning Fitting to the Phase-Domain Frequency-Dependent Modeling of Overhead Transmission LinesIEEE Transactions on Power Delivery, 2014
- State of art of power electronics in circuit breaker technology2012
- Phase domain modeling of frequency-dependent transmission lines by means of an ARMA modelIEEE Transactions on Power Delivery, 1996