Effect of Femoral Component Offset on Polyethylene Wear in Total Hip Arthroplasty
Authors:
- Peter F. SharkeyPSPeter F. Sharkey
- Kenneth EngKEKenneth Eng
- William J. HozackWHWilliam J. Hozack
- Richard H. RothmanRRRichard H. Rothman
- 1 July 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 388 (388) , 125-134
Abstract
Seventeen staged, bilateral total hip arthroplasties performed in 17 patients were reviewed to compare side-to-side polyethylene wear. Implants used on both sides were similar except for implant offset: one hip in each patient was replaced using a femoral component having a standard implant offset, whereas the other side had a lateral offset implant. The mean followup was 5.70 years (range, 2–10.2 years) on the side with a standard femoral implant and 5.67 years (range, 2–9.7 years) on the side with a lateralized femoral component. The only statistically different parameter between the sides was the femoral component offset. All other parameters affecting polyethylene wear, such as period of followup, head size, head type, cup size, cup inclination, medialization of cup, and patientrelated factors were similar on both sides. On the side with a standard femoral component, the mean actual prosthetic offset (determined by manufacturer’s specifications) was 35.2 mm and the radiologic offset was 31.5 mm. On the side with a lateralized femoral component, the actual prosthetic offset was 42.5 mm and the radiologic offset was 40.1 mm. The difference in offsets between the sides was statistically significant. The mean preoperative offset of the femur was 38.8 mm. Regression analysis revealed that only femoral component offset and cup size correlated significantly with linear wear rate. On the side with a standard femoral component, the linear wear rate was 0.21 mm per year, whereas on the side with a lateralized femoral component, the linear wear rate was 0.10 mm per year. The differences in the linear wear rates were significant. Lateralization of the femoral component in this series more closely restored preoperative hip biomechanics and significantly decreased polyethylene wear.Keywords
This publication has 28 references indexed in Scilit:
- Three-dimensional polyethylene wear of a press-fit titanium prosthesisThe Journal of Arthroplasty, 1997
- 3-Dimensional Sliding/Contact Computational Simulation of Total Hip WearClinical Orthopaedics and Related Research, 1996
- Adaptiive finite element modeling of long‐term polyethylene wear in total hip arthroplastyJournal of Orthopaedic Research, 1996
- Loss of bone stock with cementless hip arthroplastyThe Journal of Arthroplasty, 1995
- Severe polyethylene wear in total hip arthroplastyThe Journal of Arthroplasty, 1994
- Polyethylene wear in total hip arthroplasty in patient-matched groupsThe Journal of Arthroplasty, 1993
- Factors influencing survival of the socket after primary low-friction arthroplasty of the hipArchives of orthopaedic and trauma surgery, 1993
- Wear of the polyethylene acetabular cup: Metallic and ceramic heads compared in a hip simulatorActa Orthopaedica, 1993
- Unterschiede des Polyäthylenabriebs bei Hüftgelenkendoprothesen mit Keramik-und Metall-Polyäthylenpaarung der GleitflächenZeitschrift für Orthopädie und ihre Grenzgebiete, 1991
- Cementless Total Hip Arthroplasty Using the Anatomic Medullary Locking StemClinical Orthopaedics and Related Research, 1989