Accuracy of second trimester fetal head circumference and biparietal diameter for predicting the time of spontaneous birth
Authors:
- Synnøve Lian JohnsenSJSynnøve Lian Johnsen
- Svein RasmussenSRSvein Rasmussen
- Rita SollienRSRita Sollien
- Torvid KiserudTKTorvid Kiserud
- 1 January 2006
- journal article
- Published by Walter de Gruyter GmbH in Journal of Perinatal Medicine
- Vol. 34 (5) , 367-70
Abstract
Previous studies suggested that head circumference (HC) predicts the date of confinement better than the biparietal diameter (BPD). The present study aimed to prospectively test this assumption. A prospective study including 4179 consecutive women attending the second trimester routine ultrasound examination at 17-20 weeks of gestation. Outer-outer BPD and HC were determined as the average of three repeated measurements. Twins were excluded. Time of delivery was noted, the differences between this and the predicted date of delivery calculated with HC and BPD (based on a pregnancy duration of 282 days), and the two methods were compared using Wilcoxon signed rank test. For the entire group, the median differences between actual and predicted delivery with HC and BPD were 0.9 and 1.2 days, respectively. For deliveries with a spontaneous onset of labor (n=3336) the corresponding differences were 0.9 and 1.4 days. The difference between the HC and BPD methods was significant (Por=296 days) according to HC and 5.7% according to BPD. Provided that the expected pregnancy duration was 282 days, both HC and BPD predicted spontaneous birth with a mean accuracy of one day, HC being significantly better than BPD.Keywords
This publication has 20 references indexed in Scilit:
- Fetal age assessment based on ultrasound head biometry and the effect of maternal and fetal factorsActa Obstetricia et Gynecologica Scandinavica, 2004
- Routine ultrasound is the method of choice for dating pregnancyBJOG: An International Journal of Obstetrics & Gynaecology, 1998
- How accurate is fetal biometry in the assessment of fetal age?American Journal of Obstetrics and Gynecology, 1998
- New charts for ultrasound dating of pregnancyUltrasound in Obstetrics & Gynecology, 1997
- Statistics Notes: Measurement errorBMJ, 1996
- Bias in Studies of Preterm and Postterm Delivery Due to Ultrasound Assessment of Gestational AgeEpidemiology, 1995
- Ultrasound instead of last menstrual period as the basis of gestational age assignmentUltrasound in Obstetrics & Gynecology, 1991
- Fetal head circumference: relation to menstrual ageAmerican Journal of Roentgenology, 1982
- Estimating fetal age: effect of head shape on BPDAmerican Journal of Roentgenology, 1981
- THE PREDICTION OF FETAL MATURITY BY ULTRASONIC MEASUREMENT OF THE BIPARIETAL DIAMETERBJOG: An International Journal of Obstetrics & Gynaecology, 1969