Oxygen saturation profile in healthy preterm infants
Authors:
- 31 January 2011
- journal article
- Published by BMJ in Archives of Disease in Childhood - Fetal and Neonatal Edition
- Vol. 96 (5) , F339-F342
Abstract
Aim: To establish a reference range for oxygen saturation (SpO2) in well preterm infants to guide home oxygen therapy using a pulse oximeter and Pulse Oximetry Data Analysis Software (PODS). Methods: SpO2 and heart-rate profiles of healthy preterm infants receiving mechanical ventilation for less than 6 h and supplemental oxygen for less than 48 h were monitored using a pulse oximeter. The stored data were downloaded from the monitor to a personal computer as individual files. Each infant's files of SpO2 were subsequently displayed in graphic form, and a reference range was constructed using dedicated software, PODS. Results: 43 infants were studied. The median value of all infants mean SpO2 values was 95% (range 92–99%). The median duration of saturations less than 85% and between 85% and 90 % were 1% and 2% respectively. Using the study group median, 5th and 95th percentiles, a cumulative frequency curve of time against SpO2 value was constructed (representing the reference range of SpO2 profiles in healthy preterm infants). Conclusion: The SpO2 reference range can be used as an easy and practical guide to compare SpO2 profiles of infants on home oxygen therapy and guide their oxygen therapy.Keywords
This publication has 13 references indexed in Scilit:
- Target Ranges of Oxygen Saturation in Extremely Preterm InfantsNew England Journal of Medicine, 2010
- Home oxygen status and rehospitalisation and primary care requirements of infants with chronic lung diseaseArchives of Disease in Childhood, 2002
- When do infants need additional inspired oxygen? A review of the current literaturePediatric Pulmonology, 1998
- Hospitalization as a measure of morbidity among very low birth weight infants with chronic lung diseaseThe Journal of Pediatrics, 1996
- Does the duration of oxygen dependence after birth influence subsequent respiratory morbidity?European Journal of Pediatrics, 1994
- Saturation by pulse oximetry: Comparison of the results obtained by instruments of different brandsThe Journal of Pediatrics, 1993
- Arterial oxygen saturation in preterm infants at discharge from the hospital and six weeks laterThe Journal of Pediatrics, 1992
- Effect of age and state of wakefulness on transcutaneous oxygen vlaues in preterm infants: A longitudinal studyThe Journal of Pediatrics, 1988
- Home Oxygen Promotes Weight Gain in Infants With Bronchopulmonary DysplasiaArchives of Pediatrics & Adolescent Medicine, 1987
- Transcutaneous monitoring of oxygenation: What is normal?The Journal of Pediatrics, 1986