Distal Interlocking Screw Placement in the Femur
Authors:
- Sithombo MaqungoSMSithombo Maqungo
- Anria HornAHAnria Horn
- Brian BernsteinBBBrian Bernstein
- Marius KeelMKMarius Keel
- Stephen RocheSRStephen Roche
- 1 December 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 28 (12) , e281-e283
Abstract
To compare the free-hand (FH) technique of placing interlocking screws to a commercially available electromagnetic (EM) targeting system in terms of operating time, radiation dose, and accuracy of screw placement. Between September 2011 and July 2012, we prospectively randomized 100 consecutive femur shaft fractures in 99 patients requiring intramedullary nails to either FH using fluoroscopy (n = 43) or EM targeting (n = 38; Sureshot). Single Level 1 University Hospital Trauma Center. The 2 groups were assessed for distal locking with respect to time, radiation, and accuracy. Eight-one fractures had data accurately recorded (38 EM/43 FH). The average total operative time was 50 minutes (range, 25-88 minutes; SD, 13.9 minutes) for the FH group and 57 minutes (range, 40-103 minutes; SD, 16.12 minutes) for the EM group. The average time for distal locking was 10 minutes (range, 4-16 minutes; SD, 3.56 minutes) with FH and 11 minutes (range, 6-28 minutes; SD, 10.24 minutes) with EM. Average radiation dose for distal locking was significantly less (P < 0.0001) for EM at 230.54 μGy (range, 51-660 μGy; SD, 0.17 μGy) compared with 690.27 μGy (range, 200-2310 μGy; SD, 0.52 μGy) for FH. There were 2 misplaced drill bits in FH and 3 in EM. This was not statistically significant (P = 0.888). The electromagnetic targeting device (Sureshot) significantly reduced radiation exposure during placement of distal interlocking screws, without sacrificing operative time, and was equivalent in accuracy when compared with the FH technique. Therapeutic level II.Keywords
This publication has 12 references indexed in Scilit:
- Radiation-free distal locking of intramedullary nails: Evaluation of a new electromagnetic computer-assisted guidance systemInjury, 2013
- Fracture and Dislocation Classification Compendium - 2007Journal of Orthopaedic Trauma, 2007
- Literature review of current techniques for the insertion of distal screws into intramedullary locking nailsInjury, 2006
- Distal Intramedullary Nail InterlockingJournal of Orthopaedic Trauma, 2005
- Occupational Radiation Exposure to the SurgeonJournal of the American Academy of Orthopaedic Surgeons, 2005
- Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implantsInjury, 2004
- A new mechanical aiming device for the placement of distal interlocking screws in femoral nailsArchives of orthopaedic and trauma surgery, 1998
- Inserting the distal screws in a locked femoral nailThe Journal of Bone and Joint Surgery. British volume, 1991
- Intramedullary nailing of femoral shaft fractures. Part IIJournal of Bone and Joint Surgery, 1988
- Intramedullary nailing of femoral shaft fractures. Part IJournal of Bone and Joint Surgery, 1988