Experiences of the First 16 Hospitals Using Copper-Silver Ionization forLegionellaControl: Implications for the Evaluation of Other Disinfection Modalities
Authors:
- 1 August 2003
- journal article
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 24 (8) , 563-568
Abstract
Background and Objectives: Hospital-acquired legionnaires' disease can be prevented by disinfection of hospital water systems. This study assessed the long-term efficacy of copper-silver ionization as a disinfection method in controllingLegionellain hospital water systems and reducing the incidence of hospital-acquired legionnaires' disease. A standardized, evidence-based approach to assist hospitals with decision making concerning the possible purchase of a disinfection system is presented.Design: The first 16 hospitals to install copper-silver ionization systems forLegionelladisinfection were surveyed. Surveys conducted in 1995 and 2000 documented the experiences of the hospitals with maintenance of the system, contamination of water withLegionella, and occurrence of hospital-acquired legionnaires' disease. All were acute care hospitals with a mean of 435 beds.Results: All 16 hospitals reported cases of hospital-acquired legionnaires' disease prior to installing the copper-silver ionization system. Seventy-five percent had previously attempted other disinfection methods including superheat and flush, ultraviolet light, and hyperchlorination. By 2000, the ionization systems had been operational from 5 to 11 years. Prior to installation, 47% of the hospitals reported that more than 30% of distal water sites yieldedLegionella. In 1995, after installation, 50% of the hospitals reported 0% positivity, and 43% still reported 0% in 2000. Moreover, no cases of hospital-acquired legionnaires' disease have occurred in any hospital since 1995.Conclusions: This study represents the final step in a proposed 4-step evaluation process of disinfection systems that includes (1) demonstrated efficacy ofLegionellaeradication in vitro using laboratory assays, (2) anecdotal experiences in preventing legionnaires' disease in individual hospitals, (3) controlled studies in individual hospitals, and (4) validation in confirmatory reports from multiple hospitals during a prolonged time (5 to 11 years in this study). Copper-silver ionization is now the only disinfection modality to have fulfilled all four evaluation criteria.Keywords
This publication has 22 references indexed in Scilit:
- Negative Effect of High pH on Biocidal Efficacy of Copper and Silver Ions in Controlling Legionella pneumophilaApplied and Environmental Microbiology, 2002
- Ionization Failure Not Due to ResistanceClinical Infectious Diseases, 2000
- Four Years of Experience with Silver-Copper Ionization for Control of Legionella in a German University Hospital Hot Water Plumbing SystemClinical Infectious Diseases, 1999
- Treatment of aLegionella pneumophila-Colonized Water Distribution System Using Copper-Silver Ionization and Continuous ChlorinationInfection Control & Hospital Epidemiology, 1999
- A Survey of Methods Used to Detect Nosocomial Legionellosis Among Participants in the National Nosocomial Infections Surveillance SystemInfection Control & Hospital Epidemiology, 1999
- Controlling Legionella in Hospital Water Systems: Experience with the Superheat-and-Flush Method and Copper-Silver IonizationInfection Control & Hospital Epidemiology, 1998
- A Prospective Study of Spontaneous AbortionEpidemiology, 1998
- Efficacy of thermal treatment and copper-silver ionization for controlling Legionella pneumophila in high-volume hot water plumbing systems in hospitalsAmerican Journal of Infection Control, 1997
- Individual and combined effects of copper and silver ions on inactivation of Legionella pneumophilaWater Research, 1996
- Controlled Evaluation of Copper-Silver Ionization in Eradicating Legionella pneumophila from a Hospital Water Distribution SystemThe Journal of Infectious Diseases, 1994