Novel multi‐spectral short‐wave infrared imaging for assessment of human burn wound depth
Authors:
Open Access
- 26 September 2024
- journal article
- research article
- Published by Wiley in Wound Repair and Regeneration
- Vol. 32 (6) , 979-991
Abstract
Burn depth determination is critical for patient care but is currently lacking accuracy. Recent animal studies showed that Short Wave Infrared (SWIR) imaging can distinguish between superficial and deep burns. This is a first human study correlating reflectance of multiple SWIR bands using a SWIR assessment tool (SWAT) with burn depth classifications by surgeons and histology. Burns and adjacent normal skin in 11 patients with thermal injuries were imaged with visual and narrow bands centred at 1200, 1650, 1940 and 2250 nm and biopsies were taken from select areas. Reflectance intensities for each band in 273 regions of interest (ROI) were divided by the normal skin reflectance and combined into three Reflectance Indices (RIs). In addition, burns in ROIs and biopsies were classified by five surgeons and three pathologists, respectively, as superficial partial, deep partial, or full thickness. Results show that for burn depth increase classified by the surgeons, reflectance increased at 1200 and 2250, decreased at 1940, and didn't change at 1650 nm. In contrast, all three RIs increase with burn depth and predict the deep and full depths ROIs representing operable regions (Area Under Curve >0.6507, p < 0.0001). Pathologists' classification matched surgeons' classification of burn category only in eight of 21 biopsies (38.1%), but reflectance at all bands and one RI for all deep partial and full thickness biopsies were larger than in non‐biopsy normal and superficial partial thickness ROIs (p < 0.0118). In conclusion, multi‐spectral imaging with a new SWAT is a promising approach for evaluation of burn wound depth.Keywords
Funding Information
- U.S. Department of War (W81XWH‐18‐2‐0038)
- National Institutes of Health (R01‐HL156961, R21‐EB032661, R21‐HL153694)
This publication has 49 references indexed in Scilit:
- European Burns Association guidelines for the management of burn mass casualty incidents within a European response planBurns, 2022
- Agreement of clinical assessment of burn size and burn depth between referring hospitals and burn centres: A systematic reviewBurns, 2022
- A systematic review of machine learning and automation in burn wound evaluation: A promising but developing frontierBurns, 2021
- A systematic review on the quality of measurement techniques for the assessment of burn wound depth or healing potentialBurns, 2019
- ISBI Practice Guidelines for Burn CareBurns, 2016
- Bond‐selective imaging of deep tissue through the optical window between 1600 and 1850 nmJournal of Biophotonics, 2011
- The Concept of λ-Ratiometry in Fluorescence Sensing and ImagingJournal of Fluorescence, 2010
- Accuracy of early burn depth assessment by laser Doppler imaging on different days post burnBurns, 2009
- Burn depth: A reviewWorld Journal of Surgery, 1992
- Adverse reactions to indocyanine green: A case report and a review of the literatureCatheterization and Cardiovascular Diagnosis, 1989