Design of a multi-axis implantable MEMS sensor for intraosseous bone stress monitoring
Authors:
- 14 July 2009
- journal article
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 19 (8)
Abstract
The capability to assess the biomechanical properties of living bone is important for basic research as well as the clinical management of skeletal trauma and disease. Even though radiodensitometric imaging is commonly used to infer bone quality, bone strength does not necessarily correlate well with these non-invasive measurements. This paper reports on the design, fabrication and initial testing of an implantable ultra-miniature multi-axis sensor for directly measuring bone stresses at a micro-scale. The device, which is fabricated with CMOS-MEMS processes, is intended to be permanently implanted within open fractures, or embedded in bone grafts, or placed on implants at the interfaces between bone and prosthetics. The stress sensor comprises an array of piezoresistive pixels to detect a stress tensor at the interfacial area between the MEMS chip and bone, with a resolution to 100 Pa, in 1 s averaging. The sensor system design and manufacture is also compatible with the integration of wireless RF telemetry, for power and data retrieval, all within a 3 mm × 3m m× 0.3 mm footprint. The piezoresistive elements are integrated within a textured surface to enhance sensor integration with bone. Finite element analysis led to a sensor design for normal and shear stress detection. A wired sensor was fabricated in the Jazz 0.35 μm BiCMOS process and then embedded in mock bone material to characterize its response to tensile and bending loads up to 250 kPa. (Some figures in this article are in colour only in the electronic version)Keywords
This publication has 19 references indexed in Scilit:
- A novelin vivomouse model for mechanically stimulated bone adaptation – a combined experimental and computational validation studyComputer Methods in Biomechanics and Biomedical Engineering, 2008
- The clinical use of quantitative ultrasound (QUS) in the detection and management of osteoporosisIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2008
- Ultrasound and the biomechanical competence of boneIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2008
- Quantitative Ultrasound Methods to Assess Bone Mineral Status in Children: Technical Characteristics, Performance, and Clinical ApplicationPediatric Research, 2008
- A contact-type piezoresistive micro-shear stress sensor for above-knee prosthesis applicationJournal of Microelectromechanical Systems, 2001
- Concept, design and fabrication of smart orthopedic implantsMedical Engineering & Physics, 2000
- The use of low-frequency vibration measurement in orthopaedicsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1999
- Bone density in children: a review of the available techniques and indicationsEuropean Journal of Radiology, 1998
- A method suitable for in vivo measurement of bone strain in humansJournal of Biomechanics, 1997
- Multichannel strain gauge telemetry for orthopaedic implantsJournal of Biomechanics, 1988