Mixed treatment comparison of repeated measurements of a continuous endpoint: an example using topical treatments for primary open‐angle glaucoma and ocular hypertension
- 5 July 2011
- journal article
- research article
- Published by Wiley in Statistics in Medicine
- Vol. 30 (20) , 2511-2535
Abstract
Mixed treatment comparison (MTC) meta‐analyses estimate relative treatment effects from networks of evidence while preserving randomisation. We extend the MTC framework to allow for repeated measurements of a continuous endpoint that varies over time. We used, as a case study, a systematic review and meta‐analysis of intraocular pressure (IOP) measurements from randomised controlled trials evaluating topical ocular hypotensives in primary open‐angle glaucoma or ocular hypertension because IOP varies over the day and over the treatment course, and repeated measurements are frequently reported. We adopted models for conducting MTC inWinBUGS(The BUGS Project, Cambridge, UK) to allow for repeated IOP measurements and to impute missing standard deviations of the raw data using the predictive distribution from observations with standard deviations. A flexible model with an unconstrained baseline for IOP variations over time and time‐invariant random treatment effects fitted the data well. We also adopted repeated measures models to allow for class effects; assuming treatment effects to be exchangeable within classes slightly improved model fit but could bias estimated treatment effects if exchangeability assumptions were not valid. We enabled all timepoints to be included in the analysis, allowing for repeated measures to increase precision around treatment effects and avoid bias associated with selecting timepoints for meta‐analysis.The methods we developed for modelling repeated measures and allowing for missing data may be adapted for use in other MTC meta‐analyses. Copyright © 2011 John Wiley & Sons, Ltd.Keywords
This publication has 91 references indexed in Scilit:
- Conjunctival hyperaemia with the use of latanoprost versus other prostaglandin analogues in patients with ocular hypertension or glaucoma: a meta-analysis of randomised clinical trialsBritish Journal of Ophthalmology, 2008
- Performing meta-analysis with incomplete statistical information in clinical trialsBMC Medical Research Methodology, 2008
- Diurnal Variation of Axial Length, Intraocular Pressure, and Anterior Eye BiometricsInvestigative Ophthalmology & Visual Science, 2008
- Assessing Evidence Inconsistency in Mixed Treatment ComparisonsJournal of the American Statistical Association, 2006
- Simultaneous comparison of multiple treatments: combining direct and indirect evidenceBMJ, 2005
- Combination of direct and indirect evidence in mixed treatment comparisonsStatistics in Medicine, 2004
- Bayesian Measures of Model Complexity and FitJournal of the Royal Statistical Society Series B: Statistical Methodology, 2002
- Twenty-four-hour time course of intraocular pressure in healthy and glaucomatous africans: relation to sleep patterns11Each of the authors discloses any type of financial interest that is related to the manuscript and any type of personal or family ownership and discloses any interest in marketing any product, drug, instrument, or piece of equipment discussed in the manuscript.Ophthalmology, 2001
- Meta-Analysis of Migraine Headache Treatments: Combining Information from Heterogeneous DesignsJournal of the American Statistical Association, 1999
- Dorzolamide, A Topical Carbonic Anhydrase InhibitorJournal of Glaucoma, 1994