First, existing commercially available open-loop and closed-loop implantable neurostimulators are reviewed and compared in terms of their targeted application, physical size, system-level features, and performance as a medical device. Next, signal processing algorithms as the primary strength point of the closed-loop neurostimulators are reviewed, and various design and implementation requirements and trade-offs are discussed in details along with quantitative examples. The review results in a set of guidelines for algorithm selection and evaluation. Second, the implementation of an inductively-powered seizure-predicting microsystem for monitoring and treatment of intractable epilepsy is presented. The miniaturized system is comprised of two miniboards and a power receiver coil. The first board hosts a 24-channel neurostimulator system on chip [15] fabricated in a $0.13\;\mu \text{m}$ CMOS technology and performs neural recording, on-chip digital signal processing, and electrical stimulation. The second board communicates recorded brain signals as well as signal processing results wirelessly. The multilayer flexible coil receives inductively-transmitted power. The system is sized at 2 $\times$ 2 $\times$ 0.7 $\text{cm}^3$ and weighs 6 g. The approach is validated in the control of chronic seizures in vivo in freely moving rats.
Keywords
This publication has 63 references indexed in Scilit:
- Experimental observation of increased fluctuations in an order parameter before epochs of extended brain synchronizationJournal of Biological Physics, 2010
- Classification of patterns of EEG synchronization for seizure predictionClinical Neurophysiology, 2009
- Invasive EEG in Presurgical Evaluation of Epilepsy2009
- A 5 $\mu$W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine InterfacesIEEE Journal of Solid-State Circuits, 2008
- Seizure prediction: the long and winding roadBrain, 2006
- Analog Seizure Detection and Performance EvaluationIEEE Transactions on Biomedical Engineering, 2006
- An automatic warning system for epileptic seizures recorded on intracerebral EEGsClinical Neurophysiology, 2005
- Bilateral deep brain stimulation in Parkinson's disease: a multicentre study with 4 years follow-upBrain, 2005
- On the predictability of epileptic seizuresClinical Neurophysiology, 2005
- How well can epileptic seizures be predicted? An evaluation of a nonlinear methodBrain, 2003