Reduction method for intrinsic random coincidence events from 176Lu in low activity PET imaging
Authors:
- 5 February 2014
- journal article
- research article
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 7 (2) , 235-245
Abstract
For clinical studies, the effects of the intrinsic radioactivity of lutetium-based scintillators such as LSO used in PET imaging can be ignored within a narrow energy window. However, the intrinsic radioactivity becomes problematic when used in low-count-rate situations such as gene expression imaging or in-beam PET imaging. Time-of-flight (TOF) measurement capability promises not only to improve PET image quality, but also to reduce intrinsic random coincidences. On the other hand, we have developed a new reduction method for intrinsic random coincidence events based on multiple-coincidence information. Without the energy window, an intrinsic random coincidence is detected simultaneously with an intrinsic true coincidence as a multiple coincidence. The multiple-coincidence events can serve as a guide to identification of the intrinsic coincidences. After rejection of multiple-coincidence events detected with a wide energy window, data obtained included a few intrinsic random and many intrinsic true coincidence events. We analyzed the effect of intrinsic radioactivity and used Monte Carlo simulation to test both the TOF-based method and the developed multiple-coincidence-based (MC-based) method for a whole-body LSO-PET scanner. Using the TOF- and MC-based reduction methods separately, we could reduce the intrinsic random coincidence rates by 77 and 30 %, respectively. Also, the intrinsic random coincidence rate could be reduced by 84 % when the TOF+MC reduction methods were applied. The developed MC-based method showed reduced number of the intrinsic random coincidence events, but the reduction performance was limited compared to that of the TOF-based reduction method.Keywords
This publication has 21 references indexed in Scilit:
- System design of a small OpenPET prototype with 4-layer DOI detectorsRadiological Physics and Technology, 2011
- Validation of a GATE Model of $^{176}$Lu Intrinsic Radioactivity in LSO PET SystemsIEEE Transactions on Nuclear Science, 2011
- Physical and clinical performance of the mCT time-of-flight PET/CT scannerPhysics in Medicine & Biology, 2011
- Development of a small prototype for a proof-of-concept of OpenPET imagingPhysics in Medicine & Biology, 2011
- GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapyPhysics in Medicine & Biology, 2011
- The imaging performance of a LaBr3-based PET scannerPhysics in Medicine & Biology, 2009
- Direct time-of-flight for quantitative, real-time in-beam PET: a concept and feasibility studyPhysics in Medicine & Biology, 2007
- Imaging of Weak-Source Distributions in LSO-Based Small-Animal PET ScannersJournal of Nuclear Medicine, 2007
- Ex vivo cell labeling with 64 Cu–pyruvaldehyde-bis( N 4 -methylthiosemicarbazone) for imaging cell trafficking in mice with positron-emission tomographyProceedings of the National Academy of Sciences of the United States of America, 2002
- Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillatorIEEE Transactions on Nuclear Science, 1992