Revision rate of large head diameter metal-on-metal total hip arthroplasty: long-term results
Open Access
- 14 March 2026
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 146 (1) , 117
Abstract
Background To assess the long-term outcomes (minimum 10 years) of total hip arthroplasty (THA) using a large head diameter metal-on-metal (MoM) acetabular prosthesis. Methods In total, 108 primary THAs (98 patients) were performed using a Cormet MoM acetabular prosthesis. Clinical hip function, radiographic evaluation and revision rate were evaluated. Results Of the 98 patients, 15 (16 hips) followed up for < 10 years were excluded. Among the remaining 92 hips (83 patients), 35 (38.0%) had pseudotumors (PTs) detected by MRI at an average of 5.0 years after the initial THA. On radiographic evaluation, osteolysis (OL) was noted in 10 hips (10.8%) on the cup side and six hips (6.5%) on the stem side. Loosening was observed in six hips (6.5%) on the cup side, whereas no loosening was noted on the stem side. Twenty-three hips (22 patients) were switched to metal-on-polyethylene articulation between 1.2 and 14.7 years (mean: 6.3 years) postoperatively due to pain, swelling, infection, and/or implant failure. In this analysis, cup failure (OL, loosening, or both) was the highest in patients with revision surgery compared to those with PTs but not revision surgery and those without PTs. Conclusions The prevalence of PTs was 38.0%, and that of revision surgery was 25%. Some cases required revisions even after 10 years following surgery. We advise against its continued use and recommend regular clinical surveillance, such as MRI, to detect adverse reactions to metal debris and periprosthetic joint infection early.Keywords
This publication has 51 references indexed in Scilit:
- Impingement with Total Hip ReplacementJournal of Bone and Joint Surgery, 2007
- Metallosis After Contemporary Metal-on-Metal Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2006
- Impingement in Total Hip ArthroplastyThe Journal of Arthroplasty, 2005
- Metal ion levels after metal-on-metal proximal femoral replacementsThe Journal of Bone and Joint Surgery. British volume, 2005
- The importance of leg length discrepancy after total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2005
- An Unusual Lymphocytic Perivascular Infiltration in Tissues Around Contemporary Metal-on-Metal Joint ReplacementsJournal of Bone and Joint Surgery, 2005
- Metal-on-Metal Bearings and Hypersensitivity in Patients with Artificial Hip JointsJournal of Bone and Joint Surgery, 2005
- A consensus paper on metal ions in metal-on-metal hip arthroplastiesThe Journal of Arthroplasty, 2004
- SURGICAL TREATMENT OF LIMB-LENGTH DISCREPANCY FOLLOWING TOTAL HIP ARTHROPLASTYJournal of Bone and Joint Surgery, 2003
- Serum levels of cobalt and chromium in a complex modular total hip arthroplasty systemThe Journal of Arthroplasty, 2002