Do pocket‐sized ultrasound machines have the potential to be used as a tool to triage patients in obstetrics and gynecology?
- 30 July 2012
- journal article
- research article
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 40 (2) , 145-150
Abstract
Objectives: To evaluate the performance and potential impact on patient management of a pocket‐sized ultrasound machine (PUM) in comparison to high‐specification ultrasound machines (HSUM).Methods: This was an observational cohort study with 204 unselected patients in three categories: 1) women with pain and bleeding in early pregnancy (101 patients); 2) women presenting for routine obstetric ultrasound assessment (53 patients); 3) women with possible gynecological pathology (50 patients). Scans were carried out transabdominally using a PUM. A second operator repeated the examination transvaginally and/or transabdominally, depending on the clinical indication, using an HSUM. The operators were blind to each other's findings.Results: In the early pregnancy group, there was good to very good agreement between the PUM and HSUM for identifying the presence or absence of an embryo, gestational sac, fetal heart motion, pregnancy location and final diagnostic outcome (kappa coefficients, 0.844, 0.843, 0.729, 0.785 and 0.812, respectively; P < 0.0001). In the obstetric ultrasound group there was good to very good agreement for fetal presentation, placental location and placental position (kappa coefficients, 0.924, 0.924 and 0.647, respectively; P < 0.0001). In the gynecological pathology group, there was very good agreement for final diagnosis and type of ovarian mass (low risk or complex) (kappa coefficients, 0.846 and 0.930, respectively; P < 0.0001). For the measured continuous variables, there was close agreement for crown–rump length, mean sac diameter, femur length and mean diameter of an ovarian mass, but not for endometrial thickness. Neither patient demographics (age, body mass index, ethnicity) nor operator experience and familiarity with a PUM had an impact on agreement between the two machines. If a PUM had been the only equipment available for an initial assessment, only two cases would have led to a suboptimal patient management plan.Conclusion: The findings and final diagnosis in the three study groups were similar for both a PUM used transabdominally and an HSUM used transvaginally and/or transabdominally. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.Keywords
This publication has 13 references indexed in Scilit:
- Diagnostic influence of cardiovascular screening by pocket-size ultrasound in a cardiac unitEuropean Heart Journal - Cardiovascular Imaging, 2011
- Feasibility and reliability of point-of-care pocket-sized echocardiographyEuropean Heart Journal - Cardiovascular Imaging, 2011
- A Suggested Roadmap for Cardiovascular Ultrasound Research for the FutureJournal of the American Society of Echocardiography, 2011
- Point-of-Care UltrasonographyNew England Journal of Medicine, 2011
- Diagnostic Accuracy of a Hand-Held Ultrasound Scanner in Routine Patients Referred for EchocardiographyJournal of the American Society of Echocardiography, 2011
- Usefulness of a New Miniaturized Echocardiographic System in Outpatient Cardiology Consultations as an Extension of Physical ExaminationJournal of the American Society of Echocardiography, 2011
- Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) studyCardiovascular Ultrasound, 2010
- The Pocket Echocardiograph: Validation and FeasibilityEchocardiography, 2010
- A comparison of transabdominal and transvaginal ultrasonography for determination of gestational age and clinical outcomes in women undergoing early medical abortionContraception, 2010
- INVESTIGATION OF ABDOMINAL MASSES BY PULSED ULTRASOUNDThe Lancet, 1958