Bioinspired Stretchable Transducer for Wearable Continuous Monitoring of Respiratory Patterns in Humans and Animals
Open Access
- 14 July 2022
- journal article
- research article
- Published by Wiley in Advanced Materials
- Vol. 34 (33) , e2203310
Abstract
A bio‐inspired continuous wearable respiration sensor modeled after the lateral line system of fish is reported which is used for detecting mechanical disturbances in the water. Despite the clinical importance of monitoring respiratory activity in humans and animals, continuous measurements of breathing patterns and rates are rarely performed in or outside of clinics. This is largely because conventional sensors are too inconvenient or expensive for wearable sensing for most individuals and animals. The bio‐inspired air‐silicone composite transducer (ASiT) is placed on the chest and measures respiratory activity by continuously measuring the force applied to an air channel embedded inside a silicone‐based elastomeric material. The force applied on the surface of the transducer during breathing changes the air pressure inside the channel, which is measured using a commercial pressure sensor and mixed‐signal wireless electronics. The transducer produced in this work are extensively characterized and tested with humans, dogs, and laboratory rats. The bio‐inspired ASiT may enable the early detection of a range of disorders that result in altered patterns of respiration. The technology reported can also be combined with artificial intelligence and cloud computing to algorithmically detect illness in humans and animals remotely, reducing unnecessary visits to clinics.Keywords
All Related Versions
Funding Information
- Innovate UK (10004425)
- Wellcome Trust (214234/Z/18/Z)
This publication has 51 references indexed in Scilit:
- Estimation of Respiration Rate from Three-Dimensional Acceleration Data Based on Body Sensor NetworkTelemedicine and e-Health, 2011
- Rate of respiration: the forgotten vital signEmergency Nurse, 2011
- Respiration rate monitoring methods: A reviewPediatric Pulmonology, 2011
- Lateral line system of fishIntegrative Zoology, 2009
- Animal models of pain: progress and challengesNature Reviews Neuroscience, 2009
- Rapid and Precise Control of Sniffing During Olfactory Discrimination in RatsJournal of Neurophysiology, 2007
- The objective medical emergency team activation criteria: A case–control studyResuscitation, 2007
- Inherently conducting polymer modified polyurethane smart foam for pressure sensingSensors and Actuators A: Physical, 2005
- Heat transfer evaluation of the nasal thermistor techniqueIEEE Transactions on Biomedical Engineering, 1996
- Emotions and respiratory patterns: review and critical analysisInternational Journal of Psychophysiology, 1994