Rigid motion‐corrected magnetic resonance fingerprinting
Open Access
- 3 September 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (2) , 947-961
Abstract
Purpose: Develop a method for rigid body motion‐corrected magnetic resonance fingerprinting (MRF).Methods: MRF has shown some robustness to abrupt motion toward the end of the acquisition. Here, we study the effects of different types of rigid body motion during the acquisition on MRF and propose a novel approach to correct for this motion. The proposed method (MC‐MRF) follows 4 steps: (1) sliding window reconstruction is performed to produce high‐quality auxiliary dynamic images; (2) rotation and translation motion is estimated from the dynamic images by image registration; (3) estimated motion is used to correct acquired k‐space data with corresponding rotations and phase shifts; and (4) motion‐corrected data are reconstructed with low‐rank inversion. MC‐MRF was validated in a standard T1/T2 phantom and 2D in vivo brain acquisitions in 7 healthy subjects. Additionally, the effect of through‐plane motion in 2D MC‐MRF was investigated.Results: Simulation results show that motion in MRF can introduce artifacts in T1 and T2 maps, depending when it occurs. MC‐MRF improved parametric map quality in all phantom and in vivo experiments with in‐plane motion, comparable to the no‐motion ground truth. Reduced parametric map quality, even after motion correction, was observed for acquisitions with through‐plane motion, particularly for smaller structures in T2 maps.Conclusion: Here, a novel method for motion correction in MRF (MC‐MRF) is proposed, which improves parametric map quality and accuracy in comparison to no‐motion correction approaches. Future work will include validation of 3D MC‐MRF to enable also through‐plane motion correction.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/P001009/, 2)
- Fondo Nacional de Desarrollo Científico y Tecnológico (1161055, 3)
- National Institute for Health Research
- Guy's and St Thomas' NHS Foundation Trust
- King's College Hospital NHS Foundation Trust
This publication has 41 references indexed in Scilit:
- Prospective motion correction in brain imaging: A reviewMagnetic Resonance in Medicine, 2012
- Distributed Optimization and Statistical Learning via the Alternating Direction Method of MultipliersFoundations and Trends in Machine Learning, 2011
- Spiral phyllotaxis: The natural way to construct a 3D radial trajectory in MRIMagnetic Resonance in Medicine, 2011
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Matrix description of general motion correction applied to multishot imagesMagnetic Resonance in Medicine, 2005
- Fast isotropic volumetric coronary MR angiography using free‐breathing 3D radial balanced FFE acquisitionMagnetic Resonance in Medicine, 2004
- Calculation of flip angles for echo trains with predefined amplitudes with the extended phase graph (EPG)‐algorithm: Principles and applications to hyperecho and TRAPS sequencesMagnetic Resonance in Medicine, 2003
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Resampling of data between arbitrary grids using convolution interpolationIEEE Transactions on Medical Imaging, 1999
- Automatic compensation of motion artifacts in MRIMagnetic Resonance in Medicine, 1999