Heat-Transfer Characteristics of a Cryogenic Loop Heat Pipe for Space Applications
Open Access
Abstract
Infrared detectors on satellites and spacecraft require cooling to increase their measurement sensitivity. To efficiently cool infrared detectors in a zero gravity environment and in limited spaces, a cryogenic loop heat pipe (CLHP) can be used to transfer heat over a certain distance by the capillary forces generated from porous wicks without a mechanical power source. The CLHP presented in this study transfers the heat load to a condenser 0.5 m away from an evaporator at temperatures below −150 °C. The CLHP with two evaporators includes a subloop for initial start-up, and uses a pressure reduction reservoir (PRR) for the supercritical start-up from room to cryogenic temperature. Nitrogen is used as the working fluid to verify the thermal behavior of the CLHP, and the heat-transfer capacity according to the nitrogen charging pressure of the PRR is investigated. To simulate a cryogenic environment, the CLHP is installed inside a space environment simulator, including a single-stage GM (Gifford McMahon) cryocooler to cool the condenser. The CLHP is horizontally installed to simulate zero gravity. The heat-transfer characteristics are experimentally evaluated through the loop circulation of the CLHP.Keywords
Funding Information
- National Research Foundation of Korea (2017M1A3A3A02016566, 2019R1A5A808320111)
This publication has 22 references indexed in Scilit:
- Study on a loop heat pipe for a long-distance heat transport under anti-gravity conditionApplied Thermal Engineering, 2016
- Experimental study of the loop heat pipe with a flat disk-shaped evaporatorExperimental Thermal and Fluid Science, 2014
- Heat transfer characteristics of thermosyphon with N2–Ar binary mixture working fluidInternational Journal of Heat and Mass Transfer, 2013
- Experimental investigation on temperature oscillation in a miniature loop heat pipe with flat evaporatorExperimental Thermal and Fluid Science, 2012
- Impact of cooling condition and filling ratio on heat transfer limit of cryogenic thermosyphonCryogenics, 2012
- Investigation of impact of different working fluids on the operational characteristics of miniature LHP with flat evaporatorApplied Thermal Engineering, 2011
- Experimental study on capillary pumping performance of porous wicks for loop heat pipeExperimental Thermal and Fluid Science, 2010
- Experimental studies on a high performance compact loop heat pipe with a square flat evaporatorApplied Thermal Engineering, 2010
- Mathematical modeling of steady-state operation of a loop heat pipeApplied Thermal Engineering, 2009
- Loop heat pipe for cooling of high-power electronic componentsInternational Journal of Heat and Mass Transfer, 2009