Continuous, noninvasive monitoring of total hemoglobin concentration by an optoacoustic technique
- 10 June 2004
- journal article
- research article
- Published by Optica Publishing Group in Applied Optics
- Vol. 43 (17) , 3401-3407
Abstract
Measurement of total hemoglobin concentration [Hgb] is a blood test that is widely used to evaluate outpatients, hospital inpatients, and surgical patients, especially those undergoing surgery associated with extensive blood loss, rapid fluid administration, and transfusion of packed red blood cells. Current techniques for measurement of [Hgb] are invasive (requiring blood sampling) and cannot provide real-time, continuous monitoring. We propose to use an optoacoustic technique for noninvasive and continuous monitoring of [Hgb]. The high resolution of the optoacoustic technique may provide accurate measurement of [Hgb] by detection and analysis of optoacoustic signals induced by short optical pulses in blood circulating in arteries or veins. We designed, built, and tested in vitro (in both tissue phantoms and in preliminary in vivo experiments) a portable optoacoustic system for the monitoring of [Hgb] in the radial artery. The system includes a nanosecond laser operating in the near-infrared spectral range and a sensitive optoacoustic probe designed to irradiate the radial artery through the skin and detect optoacoustic signals induced in blood. Results of our studies demonstrated that (1) the slope of optoacoustic waves induced in blood in the transmission mode is linearly dependent on [Hgb] in the range from 6.2 to 12.4 g/dl, (2) optoacoustic signals can be detected despite optical attenuation in turbid tissue phantoms with a thickness of 1 cm, and (3) the optoacoustic system detects signals induced in blood circulating in the radial artery. These data suggest that the optoacoustic system can be used for accurate, noninvasive, real-time, and continuous monitoring of [Hgb].Keywords
This publication has 18 references indexed in Scilit:
- Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility studyApplied Optics, 2002
- Foreign Body Aspiration: A Presenting Sign of Juvenile Myasthenia GravisAnesthesiology, 2001
- Transfusion Medicine — Blood ConservationNew England Journal of Medicine, 1999
- Transfusion Medicine — Blood TransfusionNew England Journal of Medicine, 1999
- Continuous Monitoring of Hematocrit Values During Apheresis for Allogeneic Peripheral Blood Stem Cell CollectionJournal of Hematotherapy, 1998
- Haematocrit measurements during cardiopulmonary bypass surgery: comparison of three stat methods with a blood cell counterPerfusion, 1994
- Randomized Evaluation of Pulse Oximetry in 20,802 Patients; IIAnesthesiology, 1993
- Randomized Evaluation of Pulse Oximetry in 20,802 Patients; IAnesthesiology, 1993
- Prevention of Intraoperative Anesthesia Accidents and Related Severe Injury through Safety MonitoringAnesthesiology, 1989
- Prospective Trial of Supranormal Values of Survivors as Therapeutic Goals in High-Risk Surgical PatientsChest, 1988