Incidence and risk factors of device-associated infections and associated mortality at the intensive care in the Dutch surveillance system
Authors:
- Tjallie I. I. van der KooiTKTjallie I. I. van der Kooi
- Jan C. WilleJWJan C. Wille
- 5 December 2006
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 33 (2) , 271-278
Abstract
To examine the incidence of and risk factors for device-associated infections and associated mortality. Prospective surveillance-based study in ICUs of 19 hospitals in The Netherlands. The study included 2,644 patients without infection at admission during 1997–2000, staying in the ICU for at least 48 h. The occurrence of ventilator-associated pneumonia (VAP), central venous catheter (CVC) related bloodstream infection (CR-BSI), urinary catheter-associated urinary tract infection (CA-UTI) and risk factors was monitored. Of the ventilated patients 19% developed pneumonia (25/1,000 ventilator days); of those with a central line 3% developed CR-BSI (4/1,000 CVC days,) and of catheterized patients 8% developed CA-UTI (9/1,000 catheter days). Longer device use increased the risk for all infections, especially for CR-BSI. Independent risk factors were sex, immunity, acute/elective admission, selective decontamination of the digestive tract, and systemic antibiotics at admission, dependent upon the infection type. Crude mortality significantly differed in patients with and without CR-BSI (31% vs. 20%) and CA-UTI (27% vs. 17%) but not for VAP (26% vs. 23%). Acquiring a device-associated infection was not an independent risk factor for mortality. Being in need of ventilation or a central line, and the duration of this, contributed significantly to mortality, after adjusting for other risk factors. Device use was the major risk factor for acquiring VAP, CR-BSI and CA-UTI. Acquiring a device-associated infection was not an independent risk factor for mortality, but device use in itself was.Keywords
This publication has 36 references indexed in Scilit:
- Clinical and Economic Outcomes in Critically Ill Patients with Nosocomial Catheter-Related Bloodstream InfectionsClinical Infectious Diseases, 2005
- Nonuniform Risk of Bloodstream Infection with Increasing Central Venous Catheter-DaysInfection Control & Hospital Epidemiology, 2005
- Line Sepsis in the ICU: Prevention, Diagnosis, and ManagementSeminars in Respiratory and Critical Care Medicine, 2003
- A Review of Risk Factors for Catheter-Related Bloodstream Infection Caused by Percutaneously Inserted, Noncuffed Central Venous CathetersMedicine, 2002
- Feeding Back Surveillance Data To Prevent Hospital-Acquired InfectionsEmerging Infectious Diseases, 2001
- Nosocomial Infection in an Intensive-Care Unit Identification of Risk FactorsInfection Control & Hospital Epidemiology, 1997
- The prevalence of nosocomial infection in intensive care units in Europe. Results of the European Prevalence of Infection in Intensive Care (EPIC) Study. EPIC International Advisory CommitteeJAMA, 1995
- Incidence and risk factors of pneumonia acquired in intensive care unitsIntensive Care Medicine, 1993
- An assessment of selective surveillance methods for detecting hospital-acquired infectionThe American Journal of Medicine, 1991
- Nosocomial infection and fatality in medical and surgical intensive care unit patientsArchives of internal medicine (1960), 1988