In vivo assessment of optimal b‐value range for perfusion‐insensitive apparent diffusion coefficient imaging
- 20 July 2012
- journal article
- Published by Wiley in Medical Physics
- Vol. 39 (8) , 4832-4839
Abstract
Purpose: To assess the optimalb‐values range for perfusion‐insensitive apparent diffusion coefficient (ADC) imaging of abdominal organs using short‐duration DW‐MRI acquisitions with currently available ADC estimation methods.Methods: DW‐MRI data of 15 subjects were acquired with eightb‐values in the range of 5–800 s/mm2. The reference‐standard, a perfusion insensitive, ADC value (ADCIVIM), was computed using an intravoxel incoherent motion (IVIM) model with all acquired diffusion‐weighted images. Simulated DW‐MRI data was generated using an IVIM model with b‐values in the range of 0–1200 s/mm2. Monoexponential ADC estimates were calculated using: (1) Two‐point estimator (ADC2); (2) least squares three‐point (ADC3) estimator and; (3) Rician noise model estimator (ADCR). The authors found the optimal b‐values for perfusion‐insensitive ADC calculations by minimizing the relative root mean square error (RRMS) between the ADCIVIM and the monoexponential ADC values for each estimation method and organ.Results: Lowb‐value = 300 s/mm2 and high b‐value = 1200 s/mm2 minimized the RRMS between the estimated ADC and the reference‐standard ADCIVIM to less than 5% using the ADC3 estimator. By considering only the in vivo DW‐MRI data, the combination of low b‐value = 270 s/mm2 and high b‐value of 800 s/mm2 minimized the RRMS between the estimated ADC and the reference‐standard ADCIVIM to 3 estimator. For all estimators, the RRMS between the estimated ADC and the reference standard ADC correlated strongly with the perfusion‐fraction parameter of the IVIM model (r = [0.78–0.83], p ≤ 0.003).Conclusions: The perfusion compartment in DW‐MRI signal decay correlates strongly with the RRMS in ADC estimates from short‐duration DW‐MRI. The impact of the perfusion compartment on ADC estimations depends, however, on the choice ofb‐values and estimation method utilized. Likewise, perfusion‐related errors can be reduced to b‐values used for ADC calculations and method of estimation.Keywords
Funding Information
- National Institutes of Health (R01 RR021885)
- National Institutes of Health (R01 EB008015)
- National Institutes of Health (R03 EB008680)
- National Institutes of Health (R01 LM010033)
This publication has 33 references indexed in Scilit:
- Diffusion-weighted Magnetic Resonance Imaging for the Staging of Liver FibrosisJournal of Clinical Gastroenterology, 2011
- Malignant versus benign mediastinal lesions: quantitative assessment with diffusion weighted MR imagingEuropean Radiology, 2011
- Diffusion-weighted Endorectal MR Imaging at 3 T for Prostate Cancer: Tumor Detection and Assessment of AggressivenessRadiology, 2011
- Evaluation of the Mean and Entropy of Apparent Diffusion Coefficient Values in Chronic Hepatitis C: Correlation with Pathologic Fibrosis Stage and Inflammatory Activity GradeRadiology, 2011
- Diffusion-weighted MR Imaging of the LiverRadiology, 2010
- Reproducibility and changes in the apparent diffusion coefficients of solid tumours treated with combretastatin A4 phosphate and bevacizumab in a two-centre phase I clinical trialEuropean Radiology, 2009
- Free‐breathing diffusion‐weighted imaging for the assessment of inflammatory activity in Crohn's diseaseJournal of Magnetic Resonance Imaging, 2009
- Change in diffusion weighted MRI during liver cancer radiotherapy: Preliminary observationsActa Oncologica, 2009
- Diffusion‐weighted magnetic resonance imaging allows monitoring of anticancer treatment effects in patients with soft‐tissue sarcomasJournal of Magnetic Resonance Imaging, 2008
- Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field GradientThe Journal of Chemical Physics, 1965