Comparison of non‐invasive tear film stability measurement techniques
- 1 January 2018
- journal article
- research article
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 101 (1) , 13-17
Abstract
Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p < 0.001) but not between the hand-held device and the instrument-mounted techniques (all p > 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p < 0.05), while no significant differences were observed between the two instrument-mounted devices (all p > 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability.Keywords
This publication has 27 references indexed in Scilit:
- Compatibility of phospholipid liposomal spray with silicone hydrogel contact lens wearContact Lens and Anterior Eye, 2017
- Clinical evaluation of the Oculus KeratographContact Lens and Anterior Eye, 2012
- Methodologies to Diagnose and Monitor Dry Eye Disease: Report of the Diagnostic Methodology Subcommittee of the International Dry Eye WorkShop (2007)The Ocular Surface, 2007
- The Definition and Classification of Dry Eye Disease: Report of the Definition and Classification Subcommittee of the International Dry Eye Workshop (2007)The Ocular Surface, 2007
- Frequency of Dry Eye Diagnostic Test Procedures Used in Various Modes of Ophthalmic PracticeCornea, 2000
- Survey of Preferred Tests for Diagnosis of the Tear Film and Dry EyeCornea, 2000
- The Role of Tear Proteins in Tear Film Stability in the Dry Eye Patient and in the Rabbit1998
- Tear lipid layer structure and stability following expression of the meibomian glandsOphthalmic and Physiological Optics, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Factors Affecting Tear Film Breakup in Normal EyesArchives of Ophthalmology (1950), 1973