Defining the specificity of recombinant human erythropoietin confirmation in equine samples by liquid chromatography‐tandem mass spectrometry
- 12 December 2021
- journal article
- research article
- Published by Wiley in Drug Testing and Analysis
- Vol. 14 (4) , 676-689
Abstract
The proteotypic human EPO peptides YLLEAK (T4), SLTTLLR (T11), TITADTFR (T14), and VYSNFLR (T17) are often used to confirm the presence of recombinant human EPO (rhEPO) in equine samples. Each of these peptides contains one or more isomeric leucine or isoleucine amino acids, raising the possibility that a simple leucine/isoleucine substitution could lead to a false identification when compared with a rhEPO reference standard. To examine this possibility variants of these four peptides were analysed by LC-MS/MS. These studies indicate that confirmation of rhEPO in equine samples by immuno-affinity capture and LC-MS/MS analysis is true and accurate. It was also found that chromatography played a greater role in determining LC-MS/MS specificity than tandem mass spectrometry and that, in the case of more hydrophilic peptides, the accuracy of peptide identification could be enhanced by the inclusion of 13C and 15N labelled peptide internal standards.Keywords
This publication has 25 references indexed in Scilit:
- Application of high‐throughput IEF‐PAGE for EPO‐doping testingDrug Testing and Analysis, 2012
- Detection of EPO‐Fc fusion protein in human blood: Screening and confirmation protocols for sports drug testingDrug Testing and Analysis, 2012
- A new analytical method based on anti-EPO monolith column and LC-FAIMS-MS/MS for the detection of rHuEPOs in horse plasma and urine samplesThe Analyst, 2012
- Some Empirical Notes on the Epo Epidemic in Professional CyclingResearch Quarterly for Exercise and Sport, 2011
- Screen and confirmation of PEG‐epoetin β in equine plasmaDrug Testing and Analysis, 2010
- Confirmatory Analysis of Continuous Erythropoietin Receptor Activator and Erythropoietin Analogues in Equine Plasma by LC−MS for Doping ControlAnalytical Chemistry, 2010
- LC−MS/MS Method for Confirmation of Recombinant Human Erythropoietin and Darbepoetin α in Equine PlasmaAnalytical Chemistry, 2007
- Requirements for prediction of peptide retention time in reversed-phase high-performance liquid chromatography: Hydrophilicity/hydrophobicity of side-chains at the N- and C-termini of peptides are dramatically affected by the end-groups and locationJournal of Chromatography A, 2007
- How to discriminate between leucine and isoleucine by low energy ESI-TRAP MSnJournal of the American Society for Mass Spectrometry, 2007
- Erythropoietin production by interstitial cells of hypoxic monkey kidneysBritish Journal of Haematology, 1996