Development of wearable optical topography system for mapping the prefrontal cortex activation
- 1 April 2009
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 80 (4) , 043704
Abstract
Optical topography (OT) based on near infrared spectroscopy is effective for measuring changes in the concentrations of oxygenated hemoglobin (oxy-Hb) and deoxygenated hemoglobin (deoxy-Hb) in the brain. It can be used to investigate brain functions of subjects of all ages because it is noninvasive and less constraining for subjects. Conventional OT systems use optical fibers to irradiate the scalp and detect light transmitted through the tissue in the human head, but optical fibers limit the subject’s head position, so some small systems have been developed without using optical fibers. These systems, however, have a small number of measurement channels. We developed a prototype of a small, light, and wearable OT system that covers the entire forehead. We measured changes in the concentrations of oxy-Hb and deoxy-Hb in the prefrontal cortex while a subject performed a word fluency task. The results show typical changes in oxy-Hb and deoxy-Hb during the task and suggest that the prototype of our system can be used to investigate functions in the prefrontal cortex.Keywords
This publication has 13 references indexed in Scilit:
- Wireless miniaturized in-vivo near infrared imagingOptics Express, 2008
- Practicality of wavelength selection to improve signal-to-noise ratio in near-infrared spectroscopyNeuroImage, 2004
- Sounds and silence: An optical topography study of language recognition at birthProceedings of the National Academy of Sciences, 2003
- Differences in the hemodynamic response to event-related motor and visual paradigms as measured by near-infrared spectroscopyNeuroImage, 2003
- An fMRI Investigation of Cortical Contributions to Spatial and Nonspatial Visual Working MemoryNeuroImage, 2000
- Spontaneous oscillation of oxy- and deoxy- hemoglobin changes with a phase difference throughout the occipital cortex of newborn infants observed using non-invasive optical topographyNeuroscience Letters, 2000
- Higher-Order Brain Function Analysis by Trans-Cranial Dynamic Near-Infrared Spectroscopy ImagingJournal of Biomedical Optics, 1999
- Non-invasive functional mapping with multi-channel near infra-red spectroscopic topography in humansNeuroscience Letters, 1996
- Spatial and temporal analysis of human motor activity using noninvasive NIR topographyMedical Physics, 1995
- Intracerebral penetration of infrared lightJournal of Neurosurgery, 1992