Clip or Marker Migration 5–10 Weeks after Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Report of Two Cases
Authors:
- Robyn L. BirdwellRBRobyn L. Birdwell
- Roger J. JackmanRJRoger J. Jackman
- 1 November 2003
- journal article
- case report
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 229 (2) , 541-544
Abstract
Two women, aged 50 and 51 years, underwent stereotactic, 11-gauge vacuum-assisted biopsy from the cranial approach of small lesions in the upper outer quadrant of the right breast with removal of lesions that were detected with mammography. Postbiopsy mammograms showed the metal clip or marker at the biopsy sites in both patients. Histologic analysis of both lesions indicated atypical hyperplasia. Mammograms obtained prior to surgical excision showed caudal z-axis migration of the clip or marker to be 6.5 cm at 5 weeks and 4.5 cm at 10 weeks, respectively. By ignoring the clip or marker that had migrated to an inaccurate location and by using internal and external breast landmarks to guide presurgical excision needle localization, the biopsy sites were successfully excised in both patients.Keywords
This publication has 14 references indexed in Scilit:
- To Excise or To Sample the Mammographic Target: What Is the Goal of Stereotactic II-Gauge Vacuum-Assisted Breast Biopsy?American Journal of Roentgenology, 2002
- Atypical Ductal Hyperplasia: Can Some Lesions Be Defined as Probably Benign after Stereotactic 11-gauge Vacuum-assisted Biopsy, Eliminating the Recommendation for Surgical Excision?Radiology, 2002
- Clip Migration after 11-gauge Vacuum-assisted Stereotactic Biopsy: Case ReportRadiology, 2002
- Impact of the Continuous Infusion of Levovist on Color Doppler Sonography in Portal HypertensionAmerican Journal of Roentgenology, 2002
- Movement of a Biopsy-Site Marker Clip after Completion of Stereotactic Directional Vacuum-assisted Breast Biopsy: Case ReportRadiology, 2001
- Metallic Clip Deployment during Stereotactic Breast Biopsy: Retrospective AnalysisRadiology, 2001
- Lesions Entirely Removed during Stereotactic Biopsy: Preoperative Localization on the Basis of Mammographic Landmarks and Feasibility of Freehand Technique—Initial ExperienceRadiology, 2000
- Percutaneous removal of benign mammographic lesions: comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques.American Journal of Roentgenology, 1998
- Percutaneous removal of malignant mammographic lesions at stereotactic vacuum-assisted biopsy.Radiology, 1998
- Needle-localized breast biopsy: why do we fail?Radiology, 1997