The Harris-Galante Cementless THA: A 19- to 25-Year Follow-Up Study
Authors:
- Shu SaitoSSShu Saito
- Takao IshiiTITakao Ishii
- Sei MoriSMSei Mori
- Kunihiro HosakaKHKunihiro Hosaka
- Takashi SuzukiTSTakashi Suzuki
- Yasuaki TokuhashiYTYasuaki Tokuhashi
- 3 January 2011
- journal article
- Published by SLACK, Inc. in Orthopedics
- Vol. 34 (1) , 12
Abstract
The goal of this study was to evaluate the long-term survivorship of primary cementless total hip arthroplasty (THA) using Harris-Galante porous I acetabular and Harris-Galante porous femoral components. From July 1985 to December 1991, we performed primary cementless THA on 76 hips (70 patients). Twenty-nine patients (31 hips) died due to causes unrelated to the THA, and 6 patients (7 hips) were lost to follow-up. Of 76 hips (70 patients) studied, 38 hips (35 patients) were available for follow-up at a mean 22.5 years (range, 19–25 years) postoperatively. Mean patient age at index procedure was 51.2 years (range, 42–65 years). Average Harris Hip Score was 40.5 points preoperatively and 85.8 points at final follow-up. No patient had an early or late postoperative deep infection. Radiographically, the acetabular component fixation was stable in all 38 hips. The femoral component was bone-ingrown in 26 hips, stable-fibrous in 10, and unstable in 2. One unstable hip required revision of the femoral component. Dissociation of the polyethylene liner occurred in 3 hips without fractures of the metal locking tines and required revision of the polyethylene liner and the articular head. A total of 4 hips had documented revision, and 1 femoral component failed radiographically. The survival rate with the endpoint defined as revision surgery and radiographic loosening was 86.8% at 22.5 years of follow-up. Mean polyethylene wear was 0.085 mm/year (range, 0.031–0.15 mm). This study found that the Harris-Galante porous I acetabular and Harris-Galante porous femoral components produce excellent long-term results.Keywords
This publication has 16 references indexed in Scilit:
- Fifteen-Year to Twenty-Year Results of Cementless Harris-Galante Porous Femoral and Harris-Galante Porous I and II Acetabular ComponentsThe Journal of Arthroplasty, 2010
- The Harris-Galante porous-coated, hemispherical, polyethylene-lined acetabular component in patients under 50 years of ageThe Journal of Bone and Joint Surgery. British volume, 2008
- Porous-coated cups fixed with screws: A 12-year clinical and radiostereometric follow-up study of 50 hipsActa Orthopaedica, 2006
- Langzeitergebnisse der Harris-Galante Press-fit-PfanneZeitschrift für Orthopädie und ihre Grenzgebiete, 2005
- Uncemented Harris-Galante total hip arthroplasty in patients with osteonecrosis of the femoral headActa Orthopaedica, 2005
- Fifteen-year clinical survivorship of Harris-Galante total hip arthroplastyThe Journal of Arthroplasty, 2004
- Polyethylene liner dissociation in Harris-Galante acetabular components: A report of 7 casesThe Journal of Arthroplasty, 2002
- The Harris-Galante total hip arthroplastyThe Journal of Arthroplasty, 2001
- The Harris-Galante Porous-Coated Acetabular Component with Screw Fixation. An Average Ten-Year Follow-up Study*Journal of Bone and Joint Surgery, 1999
- THE LONG-TERM RESULTS OF LOW-FRICTION ARTHROPLASTY OF THE HIP PERFORMED AS A PRIMARY INTERVENTIONThe Journal of Bone and Joint Surgery. British volume, 1972