Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure
Authors:
- 1 September 2015
- journal article
- research article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 123 (3) , 743-747
Abstract
OBJECT: Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) is known to be an accurate monitor of elevated intracranial pressure (ICP). However, it is yet unknown whether fluctuations in ICP result in direct changes in ONSD. Therefore, the authors researched whether ONSD and ICP simultaneously change during tracheal manipulation in patients in the intensive care unit (ICU) who have suffered a traumatic brain injury (TBI). MATERIALS: The authors included 18 ICP-monitored patients who had sustained TBI and were admitted to the ICU. They examined the optic nerve sheath by performing ultrasound before, during, and after tracheal manipulation, which is known to increase ICP. The correlation between ONSD and ICP measurements was determined, and the diagnostic performance of ONSD measurement was tested using receiver operating characteristic curve analysis. RESULTS: In all patients ICP increased above 20 mm Hg during manipulation of the trachea, and this increase was directly associated with a dilation of the ONSD of > 5.0 mm. After tracheal manipulation stopped, ICP as well as ONSD decreased immediately to baseline levels. The correlation between ICP and ONSD was high (R2 = 0.80); at a cutoff of ≥ 5.0 mm ONSD, a sensitivity of 94%, a specificity of 98%, and an area under the curve of 0.99 (95% CI 0.97–1.00) for detecting elevated ICP were determined. CONCLUSIONS: In patients who have sustained a TBI, ultrasonography of the ONSD is an accurate, simple, and rapid measurement for detecting elevated ICP as well as immediate changes in ICP. Therefore, it might be a useful tool to monitor ICP, especially in conditions in which invasive ICP monitoring is not available, such as at trauma scenes.Keywords
This publication has 18 references indexed in Scilit:
- Can ocular ultrasound predict intracranial hypertension? A pilot diagnostic accuracy evaluation in a UK emergency departmentEuropean Journal of Emergency Medicine, 2013
- Prehospital management of severe traumatic brain injuryCurrent Opinion in Anaesthesiology, 2012
- Comparison of accuracy of optic nerve ultrasound for the detection of intracranial hypertension in the setting of acutely fluctuating vs stable intracranial pressure: post-hoc analysis of data from a prospective, blinded single center studyCritical Care, 2012
- Ocular Ultrasound to Detect Intracranial Hypertension in Trauma PatientsJournal of Trauma: Injury, Infection & Critical Care, 2011
- Are ultrasonography measurements of optic nerve sheath diameter an alternative to funduscopy in children with syndromic craniosynostosis?Journal of neurosurgery. Pediatrics, 2011
- Predictive value of initial computerized tomography scan, intracranial pressure, and state of autoregulation in patients with traumatic brain injuryJournal of Neurosurgery, 2006
- External ventricular drain infection: the effect of a strict protocol on infection rates and a review of the literatureBritish Journal Of Neurosurgery, 2006
- Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion testsJournal of Neurosurgery, 1997
- The outcome with aggressive treatment in severe head injuriesJournal of Neurosurgery, 1979
- The outcome from severe head injury with early diagnosis and intensive managementJournal of Neurosurgery, 1977