Characterizing System Performance in Total Internal Reflection Fluorescence Microscopy
Authors:
- Ireen KönigIKIreen König
- Kurt I. AndersonKAKurt I. Anderson
- 17 June 2011
- book chapter
- Published by Springer Nature
- Vol. 769, 373-386
Abstract
Total internal reflection fluorescence microscopy (TIRF-M) has become an increasingly popular tool to study events in close proximity to the cell cortex, such as cell adhesion (Axelrod, J Cell Biol 89:141–145, 1981; Gingell et al., J Cell Biol 100:1334–1338, 1985; Patel et al., J Cell Sci 121:1159–1164, 2008), actin (Bretschneider et al., Curr Biol 14:1–10, 2004; Gerisch, Biophys J 87:3493–3503, 2004; Merrifield et al., Nat Cell Biol 4:691–698, 2002), and membrane dynamics (Oheim et al., Eur Biophys J 27:83–98, 1998; Steyer et al., Nature 388:474–478, 1997; Weisswange et al., J Cell Sci 118:4375–4380, 2005). In TIRF-M, dim fluorescence from cortical structures can be imaged with high contrast despite large cytoplasmic background from the bulk of the cell body. With any imaging method, standard samples are required to ensure correct alignment and monitor system performance over time. Here, we describe procedures for the production and use of a test sample to characterise and optimize TIRF system performance.Keywords
This publication has 13 references indexed in Scilit:
- Partial internal reflections on total internal reflection fluorescent microscopyTrends in Cell Biology, 2009
- The multi-FERM-domain-containing protein FrmA is required for turnover of paxillin-adhesion sites during cell migration of DictyosteliumJournal of Cell Science, 2008
- Direct measurement of the evanescent field profile produced by objective-based total internal reflection fluorescenceJournal of Biomedical Optics, 2006
- The leading edge is a lipid diffusion barrierJournal of Cell Science, 2005
- Refractive index measurement in viable cells using quantitative phase‐amplitude microscopy and confocal microscopyCytometry Part A, 2005
- Mobile Actin Clusters and Traveling Waves in Cells Recovering from Actin DepolymerizationBiophysical Journal, 2004
- Dynamic Actin Patterns and Arp2/3 Assembly at the Substrate-Attached Surface of Motile CellsCurrent Biology, 2004
- Lighting up the cell surface with evanescent wave microscopyTrends in Cell Biology, 2001
- Topography of cell-glass apposition revealed by total internal reflection fluorescence of volume markers.Journal of Cell Biology, 1985
- Cell-substrate contacts illuminated by total internal reflection fluorescence.Journal of Cell Biology, 1981