Proton beam therapy (PBT) is the preferred modality for early-stage lung cancer. Compared with X-ray therapy, PBT offers good dose concentration as revealed by the characteristics of the Bragg peak. Rib fractures (RFs) after PBT lead to decreased quality of life for patients. However, the incidence of and the risk factors for RFs after PBT have not yet been clarified. We therefore explored the relationship between irradiated rib volume and RFs after PBT for early-stage lung cancer. The purpose of this study was to investigate the incidence and the risk factors for RFs following PBT for early-stage lung cancer. We investigated 52 early-stage lung cancer patients and analyzed a total of 215 irradiated ribs after PBT. Grade 2 RFs occurred in 12 patients (20 ribs); these RFs were symptomatic without displacement. No patient experienced more severe RFs. The median time to grade 2 RFs development was 17 months (range: 9-29 months). The three-year incidence of grade 2 RFs was 30.2%. According to the analysis comparing radiation dose and rib volume using receiver operating characteristic curves, we demonstrated that the volume of ribs receiving more than 120 Gy3 (relative biological effectiveness (RBE)) was more than 3.7 cm(3) at an area under the curve of 0.81, which increased the incidence of RFs after PBT (P < 0.001). In this study, RFs were frequently observed following PBT for early-stage lung cancer. We demonstrated that the volume of ribs receiving more than 120 Gy3 (RBE) was the most significant parameter for predicting RFs.Keywords
This publication has 30 references indexed in Scilit:
- Radiation-Induced Rib Fractures After Hypofractionated Stereotactic Body Radiation Therapy: Risk Factors and Dose–Volume RelationshipInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Dosimetric predictors of chest wall pain after lung stereotactic body radiotherapyRadiotherapy and Oncology, 2012
- Chest Wall Toxicity After Stereotactic Body Radiotherapy for Malignant Lesions of the Lung and LiverInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Chest Wall Volume Receiving >30 Gy Predicts Risk of Severe Pain and/or Rib Fracture After Lung Stereotactic Body RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Outcome in a Prospective Phase II Trial of Medically Inoperable Stage I Non–Small-Cell Lung Cancer Patients Treated With Stereotactic Body RadiotherapyJournal of Clinical Oncology, 2009
- Comparison of surface doses from spot scanning and passively scattered proton therapy beamsPhysics in Medicine & Biology, 2009
- Can protons improve SBRT for lung lesions? Dosimetric considerationsRadiotherapy and Oncology, 2008
- Scatter factors in proton therapy with a broad beamPhysics in Medicine & Biology, 2006
- Cough-Induced Rib FracturesMayo Clinic Proceedings, 2005
- Tolerance of normal tissue to therapeutic irradiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1991