Impaired cardiac function in chronic fatigue syndrome measured using magnetic resonance cardiac tagging
Open Access
- 27 July 2011
- journal article
- research article
- Published by Wiley in Journal of Internal Medicine
- Vol. 271 (3) , 264-270
Abstract
Abstract. Hollingsworth KG, Hodgson T, MacGowan GA, Blamire AM, Newton JL (Institute of Cellular Medicine, Campus for Ageing and Vitality; Institute of Genetic Medicine; and Institute for Ageing and Health, Campus for Ageing and Vitality; Newcastle University, Newcastle, UK). Impaired cardiac function in chronic fatigue syndrome measured using magnetic resonance cardiac tagging. J Intern Med 2012; 271: 264–270.Objectives. Impaired cardiac function has been confirmed in patients with chronic fatigue syndrome (CFS). Magnetic resonance cardiac tagging is a novel technique that assesses myocardial wall function in vivo. We hypothesized that patients with CFS may have impaired development and release of myocardial torsion and strain.Methods. Cardiac morphology and function were assessed using magnetic resonance imaging and cardiac tagging methodology in 12 CFS patients (Fukuda) and 10 matched controls.Results. Compared to controls, the CFS group had substantially reduced left ventricular mass (reduced by 23%), end‐diastolic volume (30%), stroke volume (29%) and cardiac output (25%). Residual torsion at 150% of the end‐systolic time was found to be significantly higher in the patients with CFS (5.3 ± 1.6°) compared to the control group (1.7 ± 0.7°, P = 0.0001). End‐diastolic volume index correlated negatively with both torsion‐to‐endocardial‐strain ratio (TSR) (r = −0.65, P = 0.02) and the residual torsion at 150% end‐systolic time (r = −0.76, P = 0.004), so decreased end‐diastolic volume is associated with raised TSR and torsion persisting longer into diastole. Reduced end‐diastolic volume index also correlated significantly with increased radial thickening (r = −0.65, P = 0.03) and impaired diastolic function represented by the ratio of early to late ventricular filling velocity (E/A ratio, r = 0.71, P = 0.009) and early filling percentage (r = 0.73, P = 0.008).Conclusion. Patients with CFS have markedly reduced cardiac mass and blood pool volumes, particularly end‐diastolic volume: this results in significant impairments in stroke volume and cardiac output compared to controls. The CFS group appeared to have a delay in the release of torsion.Keywords
This publication has 19 references indexed in Scilit:
- Impaired cardiovascular response to standing in Chronic Fatigue SyndromeEuropean Journal of Clinical Investigation, 2010
- Chronic fatigue syndrome: illness severity, sedentary lifestyle, blood volume and evidence of diminished cardiac functionClinical Science, 2009
- Cardiac function fluctuates during exacerbation and remission in young adults with chronic fatigue syndrome and “small heart”Journal of Cardiology, 2009
- Circumferential Strain Analysis Identifies Strata of Cardiomyopathy in Duchenne Muscular DystrophyJACC, 2009
- Small Heart Syndrome in Patients with Chronic Fatigue SyndromeClinical Cardiology, 2008
- Impaired subendocardial contractile myofiber function in asymptomatic aged humans, as detected using MRIAmerican Journal of Physiology-Heart and Circulatory Physiology, 2006
- Age-Related Changes in Myocardial Relaxation Using Three-Dimensional Tagged Magnetic Resonance ImagingJournal of Cardiovascular Magnetic Resonance, 2003
- Transmural gradients of cardiac myofiber shortening in aortic valve stenosis patients using MRI taggingAmerican Journal of Physiology-Heart and Circulatory Physiology, 2002
- Noninvasive quantification of left ventricular rotational deformation in normal humans using magnetic resonance imaging myocardial tagging.Circulation, 1990
- A model of the mechanics of the left ventricleAnnals of Biomedical Engineering, 1979