Optimization of Intervention Strategies for Masonry Buildings Based on CLT Components
Open Access
- 10 August 2022
- Vol. 5 (3) , 2142-2159
Abstract
Unreinforced masonry has been for centuries one of the most widespread constructive techniques for both massive structures and civil buildings (e.g., palaces, hospitals, houses), for the most still standing nowadays. Their future conservation relies on (i) their protection from main natural threats (e.g., earthquakes) and (ii) updating to current functionality and hygrothermal standards. In the former framework, existing masonry buildings proved to have some intrinsic vulnerabilities, depending on composition (units and binder) and structural typologies. Based on experience gathered from seismic events, various retrofitting techniques have been proposed. In such a context, the use of cross-laminated timber (CLT) components is a very promising solution, in terms of compatibility with built heritage and integration of seismic and hygrothermal performances. This paper aims at improving the knowledge of the structural performances of compound timber–masonry interventions by numerical simulations carried out at (i) pier scale and (ii) building full scale via finite element modeling and nonlinear static analyses (pushover). First, a coupled timber–masonry wall was simulated and underwent sensitivity analyses with the properties of both components varying; then, the optimized solution was applied to a case study to assess the intervention benefits, and the results were also cross-checked with those of more traditional interventions (e.g., grout injections).Keywords
Funding Information
- Veneto Region
- Italian Civil Protection Department—Network of University Labs on Seismic Engineering
This publication has 66 references indexed in Scilit:
- Performance of masonry buildings during the Emilia 2012 earthquakeBulletin of Earthquake Engineering, 2013
- Seismic Behavior of Unreinforced and Confined Brick Masonry Walls Before and After Ferrocement Overlay RetrofittingInternational Journal of Architectural Heritage, 2012
- Experimental Evaluation of the In‐Plane Stiffness of Timber DiaphragmsEarthquake Spectra, 2012
- Elastic and ductile design of multi-storey crosslam massive wooden buildings under seismic actionsEngineering Structures, 2011
- Structural Aspects of The Conservation of Historic Masonry Constructions in Seismic Areas: Remedial Measures and Emergency ActionsInternational Journal of Architectural Heritage, 2011
- Assessment and analysis of damage in L’Aquila historic city centre after 6th April 2009Bulletin of Earthquake Engineering, 2010
- An application of EMS98 in a medium-sized city: The case of L’Aquila (Central Italy) after the April 6, 2009 Mw 6.3 earthquakeBulletin of Earthquake Engineering, 2010
- Experimental evaluation of shear and compression strength of masonry wall before and after reinforcement: Deep repointingConstruction and Building Materials, 2008
- Mechanical behaviour of historic masonry structures strengthened by bed joints structural repointingConstruction and Building Materials, 2005
- Experimental and analytical studies for the choice of repair techniques applied to historic buildingsMaterials and Structures, 2002