Performance of Different Accelerometry-Based Metrics to Estimate Oxygen Consumption during Track and Treadmill Locomotion over a Wide Intensity Range
Open Access
Abstract
Accelerometer data can be used to estimate incident oxygen consumption (VO2) during physical activity. Relationships between the accelerometer metrics and VO2 are typically determined using specific walking or running protocols on a track or treadmill. In this study, we compared the predictive performance of three different metrics based on the mean amplitude deviation (MAD) of the raw three-dimensional acceleration signal during maximal tests performed on a track or treadmill. A total of 53 healthy adult volunteers participated in the study, 29 performed the track test and 24 the treadmill test. During the tests, the data were collected using hip-worn triaxial accelerometers and metabolic gas analyzers. Data from both tests were pooled for primary statistical analysis. For typical walking speeds at VO2 less than 25 mL/kg/min, accelerometer metrics accounted for 71–86% of the variation in VO2. For typical running speeds starting from VO2 of 25 mL/kg/min up to over 60 mL/kg/min, 32–69% of the variation in VO2 could be explained, while the test type had an independent effect on the results, except for the conventional MAD metrics. The MAD metric is the best predictor of VO2 during walking, but the poorest during running. Depending on the intensity of locomotion, the choice of proper accelerometer metrics and test type may affect the validity of the prediction of incident VO2.Keywords
This publication has 28 references indexed in Scilit:
- The Physical Activity Guidelines for AmericansJAMA, 2018
- Establishing cut-points for physical activity classification using triaxial accelerometer in middle-aged recreational marathonersPLOS ONE, 2018
- Reliable recognition of lying, sitting, and standing with a hip‐worn accelerometerScandinavian Journal of Medicine & Science in Sports, 2017
- Intensity Thresholds on Raw Acceleration Data: Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) ApproachesPLOS ONE, 2016
- A comparison of variability in spatiotemporal gait parameters between treadmill and overground walking conditionsGait & Posture, 2016
- Validity of treadmill- and track-based individual calibration methods for estimating free-living walking speed and VO2 using the Actigraph accelerometerBMC Sports Science, Medicine and Rehabilitation, 2015
- Validation of Cut-Points for Evaluating the Intensity of Physical Activity with Accelerometry-Based Mean Amplitude Deviation (MAD)PLOS ONE, 2015
- A universal, accurate intensity‐based classification of different physical activities using raw data of accelerometerClinical Physiology and Functional Imaging, 2014
- A kinematic and kinetic comparison of overground and treadmill walking in healthy subjectsGait & Posture, 2007
- Effect of Monitor Placement and of Activity Setting on the MTI Accelerometer OutputMedicine & Science in Sports & Exercise, 2003