Coagulation patterns following haemoglobin‐based oxygen carrier resuscitation in severe uncontrolled haemorrhagic shock in swine
Authors:
- 25 July 2006
- journal article
- Published by Wiley in Transfusion Medicine
- Vol. 16 (4) , 290-302
Abstract
Massive blood loss due to penetrating trauma and internal organ damage can cause severe haemorrhagic shock (HS), leading to a severely compromised haemostatic balance. This study evaluated the effect of bovine polymerized haemoglobin (Hb) (Hb-based oxygen carrier, HBOC) resuscitation on haemostasis in a swine model of uncontrolled HS. Following liver injury/HS, swine received HBOC (n= 8), Hextend (HEX) (n= 8) or no resuscitation (NON) (n= 8). Fluids were infused to increase mean arterial pressure above 60 mmHg and to reduce heart rate to baseline. At 4 h, the animals were eligible for blood transfusions. Prothrombin time (PT), activated partial thromboplastin time, fibrinogen, thromboelastography (TEG) and platelet function analyser closure time (PFA-CT) were compared by using mixed statistical model. At 4 h, blood loss (% estimated blood volume) was comparable for HBOC (65.5 +/- 18.5%) and HEX (80.8 +/- 14.4%) and less for NON (58.7 +/- 10.1%; P < 0.05). Resuscitation-induced dilutional coagulopathy was observed with HBOC and HEX, as indicated by reduced haematocrit, platelets and fibrinogen (P < 0.05). At 4 h, PT was higher in HEX than in HBOC groups (P < 0.01). In the early hospital phase, a trend to increased TEG reaction time and PFA-CT indicates that dilutional effects persist in HBOC and HEX groups. PFA-CT returned to baseline later with HBOC than with HEX (48 vs. 24 h) following blood transfusion. At 4 h, all surviving HEX animals (n= 3) required transfusion, in contrast to no HBOC (n= 7) or NON (n= 1) animals. In this severe uncontrolled HS model, successful resuscitation with HBOC produced haemodilutional coagulopathy less than or similar to that produced by resuscitation with HEX.Keywords
This publication has 37 references indexed in Scilit:
- Bovine polymerized hemoglobin (hemoglobin-based oxygen carrier-201) resuscitation in three swine models of hemorrhagic shock with militarily relevant delayed evacuation—Effects on histopathology and organ function*Critical Care Medicine, 2006
- A hemoglobin-based oxygen carrier, bovine polymerized hemoglobin (HBOC-201) versus hetastarch (HEX) in a moderate severity hemorrhagic shock swine model with delayed evacuationResuscitation, 2005
- EFFECTS OF BOVINE POLYMERIZED HEMOGLOBIN ON COAGULATION IN CONTROLLED HEMORRHAGIC SHOCK IN SWINEShock, 2005
- Sepsis and CoagulationCritical Care Clinics, 2005
- The use of haemoglobin glutamer-250 (HBOC-201) as an oxygen bridge in patients with acute anaemia associated with surgical blood lossExpert Opinion on Biological Therapy, 2003
- Hemoglobin-based oxygen carriers do not alter platelet functions: study of three chemically modified hemoglobin solutionsIntensive Care Medicine, 2003
- Emerging Infectious Agents: Do They Pose a Risk to the Safety of Transfused Blood and Blood Products?Clinical Infectious Diseases, 2002
- Hemoglobin stimulates the release of proinflammatory cytokines from leukocytes in whole bloodJournal of Laboratory and Clinical Medicine, 2000
- Hemoglobin-based oxygen carrier preserves submaximal exercise capacity in humans*Clinical Pharmacology & Therapeutics, 1995
- Hematocrit and Bleeding Time: An UpdateSouthern Medical Journal, 1994