Diagnosis of Open-Phase Faults for a Five-Phase PMSM Fed by a Closed-Loop Vector-Controlled Drive Based on Magnetic Field Pendulous Oscillation Technique
- 10 June 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (7) , 5582-5593
Abstract
An on-line diagnostic approach of open-phase faults for a five-phase permanent magnet synchronous motor (PMSM) fed by a closed-loop vector-controlled drive is presented in this paper. This approach is accomplished based on the magnetic field pendulous oscillation (MFPO) phenomenon, in which a significant “swing-like” pendulous oscillation in the magnetic field is observed in case of open-phase faults. According to analysis of the signatures of MFPO patterns under faulty conditions, all possible open-phase faults are detected, including single-phase open faults, two-adjacent phase open faults, and two-nonadjacent phase open faults. Moreover, this approach is capable of localizing the faulted phase/phases by further extracting the phase angle features of MFPO angular position waveforms under faulty conditions. Meanwhile, in order to minimize the number of sensors to reduce the implementation cost of this diagnostic approach, a phase-locked loop (PPL) technique is developed to overcome the fault masking difficulties associated with the compensation action of the closed-loop vector-controlled drive. As a result, this diagnostic approach only requires four current sensors and a speed sensor, which are typically already available in five-phase PMSM drive systems for control purpose. Finally, experimental results demonstrate the effectiveness of the presented approach.Keywords
Funding Information
- Marquette University
- Motor Design, Ltd.
- Kollmorgen Corporation, Regal Beloit America, Inc.
- MTS System Corporation
- Nanyang Technological University (M4082346.040.601001)
This publication has 32 references indexed in Scilit:
- An Inverse Approach for Interturn Fault Detection in Asynchronous Machines Using Magnetic Pendulous Oscillation TechniqueIEEE Transactions on Industry Applications, 2015
- Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part IIEEE Transactions on Industrial Electronics, 2015
- Online Detection of High-Resistance Connections in Multiphase Induction MachinesIEEE Transactions on Power Electronics, 2014
- D-Q Current Signature-Based Faulted Phase Localization for SM-PMAC Machine DrivesIEEE Transactions on Industrial Electronics, 2014
- Effects of Load Magnitude on Diagnosing Broken Bar Faults in Induction Motors Using the Pendulous Oscillation of the Rotor Magnetic Field OrientationIEEE Transactions on Industry Applications, 2005
- Five-Phase Permanent-Magnet Motor DrivesIEEE Transactions on Industry Applications, 2005
- Induction Machine Broken-Bar Fault Diagnosis Using the Rotor Magnetic Field Space-Vector OrientationIEEE Transactions on Industry Applications, 2004
- IPM synchronous machine drive response to a single-phase open circuit faultIEEE Transactions on Power Electronics, 2002
- Closed-loop control impact on the diagnosis of induction motors faultsIEEE Transactions on Industry Applications, 2000
- Operation of a phase locked loop system under distorted utility conditionsIEEE Transactions on Industry Applications, 1997