An improved analytical method for the determination of urea nitrogen isotopomers in biological samples utilizing continuous flow isotope ratio mass spectrometry
Authors:
- 13 November 2006
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (24) , 3736-3740
Abstract
Over the past few years numerous dual inlet isotope ratio mass spectrometry (IRMS) applications have been adapted to continuous flow systems which allow the automation of sample admission and a higher throughput. The isotopomer analysis of urea nitrogen by IRMS requires the offline conversion of urea into nitrogen gas before analysis. The oxidation of urea with LiOBr results in the monomolecular degradation of urea, which preserves the identity of the parent urea molecule, and has to be conducted under vacuum to prevent contamination with atmospheric nitrogen. We have developed an offline system of urea degradation utilizing disposable Exetainers, in which atmospheric nitrogen is displaced by helium. Recovery of urea nitrogen was linear within the range of the standards tested (0 to 420 µg nitrogen) and standard curves for 15 N 15 N‐urea standards showed high coefficients of determination (R 2 > 0.9998). A small portion of urea degrades in a non‐monomolecular fashion and has been shown to depend on the concentration of urea in the sample. Long‐term storage of prepared samples showed a decline in 15 N 15 N enrichment, suggesting air contamination. However, samples were stable for 24 h, which allows for the analysis of large sample batches. Interest in urea metabolism, particularly in ruminant species, has increased recently due to the environmental implications of urea and nitrogen excretion by farm animals. This novel analytical method will allow for accurate measurements and the rapid throughput needed in order to support these field studies. Copyright © 2006 John Wiley & Sons, Ltd.Keywords
This publication has 22 references indexed in Scilit:
- δ 13 C analyses of calcium carbonate: comparison between the GasBench and elemental analyzer techniquesRapid Communications in Mass Spectrometry, 2006
- Automated analyses of 18O/16O ratios in dissolved oxygen from 12‐mL water samplesLimnology and Oceanography: Methods, 2004
- Changes in Composition of Nitrogen‐15‐Labeled Gases during Storage in Septum‐Capped VialsSoil Science Society of America Journal, 2003
- Low‐abundance plasma and urinary [15N]urea enrichments analyzed by gas chromatography/combustion/isotope ratio mass spectrometryJournal of Mass Spectrometry, 2002
- A Mass Isotopomer Study of Urea and Glutamine Synthesis from 15N-labeled Ammonia in the Perfused Rat LiverJournal of Biological Chemistry, 1996
- Measurement of15N enrichment in multiple amino acids and urea in a single analysis by gas chromatography/mass spectrometryJournal of Mass Spectrometry, 1993
- Rapid sample throughput for biomedical stable isotope tracer studiesJournal of Mass Spectrometry, 1988
- Nitrogen digestion and metabolism in sheep consuming diets containing contrasting forms and levels of NBritish Journal of Nutrition, 1985
- Dynamic aspects of ammonia and urea metabolism in sheepBritish Journal of Nutrition, 1972
- Altered Proportions of Isotopes of Molecular Nitrogen as Evidence for a Monomolecular ReactionThe Journal of Chemical Physics, 1954