In vivomonitoring of bone–implant bond strength by microCT and finite element modelling
- 1 September 2013
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 16 (9) , 993-1001
Abstract
Immediately after implantation, a dynamic process of bone formation and resorption takes place around an orthopaedic implant, influencing its mechanical fixation. The delay until complete fixation depends on local bone architecture and metabolism. Despite its importance, the temporal pattern of implant fixation is still unknown. The optimal duration of post-operative care is therefore difficult to establish for an individual situation, and a method to evaluate non-invasively the evolution of the mechanical stability would be a significant asset in a clinical environment. The aim of this study was to evaluate the potential of micro-finite element modelling based on in vivo micro-computed tomography to monitor longitudinally the contact between bone and implant and the implant strength in vivo. The model was first validated for screw pull-out in synthetic bone surrogate. Correlation coefficients of R2 = 0.94 and 0.85 (p < 0.01) were measured between experimental and numerical results for stiffness and failure loads, respectively. Then, the mechanical integration of screws in the proximal tibia of 12 rats was monitored at seven time points over a period of 1 month. We observed significant increases (p < 0.05) of bone–screw contact (+28%), stiffness (+93%) and failure load (+71%) over the course of the experiment, and more than 75% of these changes occurred during the first 2 weeks. Limitations, such as image artefacts and radiation, still compromise the immediate clinical application of this method, but it has a promising potential in preclinical animal studies, as it provides very valuable data about the dynamic aspect of implant integration with considerably reduced animal resources.Keywords
This publication has 33 references indexed in Scilit:
- Computational biomechanics of the distal tibia from high-resolution MR and micro-CT imagesBone, 2010
- Extreme scalability challenges in micro‐finite element simulations of human boneConcurrency and Computation: Practice and Experience, 2010
- On cone‐beam computed tomography artifacts induced by titanium implantsClinical Oral Implants Research, 2009
- Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMDBone, 2009
- Influence of bone density on implant stability parameters and implant success: a retrospective clinical studyBMC Oral Health, 2008
- Computed Tomographic Metal Artifact Reduction for the Detection and Quantitation of Small Features Near Large Metallic ImplantsJournal of Computer Assisted Tomography, 2008
- No effects of in vivo micro‐CT radiation on structural parameters and bone marrow cells in proximal tibia of wistar rats detected after eight weekly scansJournal of Orthopaedic Research, 2007
- Calcium phosphate drug delivery system: influence of local zoledronate release on bone implant osteointegrationBone, 2005
- High-Resolution Three-Dimensional-pQCT Images Can Be an Adequate Basis for In-Vivo μFE Analysis of BoneJournal of Biomechanical Engineering, 2000
- A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element modelsJournal of Biomechanics, 1995