Validation of a 1D patient-specific model of the arterial hemodynamics in bypassed lower-limbs: Simulations against in vivo measurements
Authors:
- Valérie LacroixVLValérie Lacroix
- Emilie MarchandiseEMEmilie Marchandise
- 21 May 2013
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 35 (11) , 1573-1583
Abstract
The validation of a coupled 1D-0D model of the lower-limb arterial hemodynamics is presented. This study focuses on pathological subjects (6 patients, 72.7±11.1 years) suffering from atherosclerosis who underwent a femoro-popliteal bypass surgery. The 1D model comprises four vessels from the upper-leg, peripheral networks are modeled with three-element windkessels and in vivo velocity is prescribed at the inlet. The model is patient-specific: its parameters reflect the physiological condition of the subjects. In vivo data are acquired invasively during bypass surgery using B-mode ultrasonography and catheter. Simulations from the model compare well with measured velocity (u) and pressure (p) waveforms: average relative root-mean-square error between numerical and experimental waveforms are limited to εp=9.6%, εu=16.0%. The model is able to reproduce the intensity and shape of waveforms observed in different clinical cases. This work also details the introduction of blood leakages along the pathological arterial network, and the sensitivity of the model to its parameters. This study constitutes a first validation of a patient-specific numerical model of a pathological arterial network. It presents an efficient tool for engineers and clinicians to help them improve their understanding of the hemodynamics in diseased arteries.Keywords
This publication has 26 references indexed in Scilit:
- Validation of a patient-specific one-dimensional model of the systemic arterial treeAmerican Journal of Physiology-Heart and Circulatory Physiology, 2011
- Pulse wave propagation in a model human arterial network: Assessment of 1-D visco-elastic simulations against in vitro measurementsJournal of Biomechanics, 2011
- Estimation of distributed arterial mechanical properties using a wave propagation model in a reverse wayMedical Engineering & Physics, 2010
- Validation of a one-dimensional model of the systemic arterial treeAmerican Journal of Physiology-Heart and Circulatory Physiology, 2009
- Predictive Haemodynamics in a One-Dimensional Human Carotid Artery Bifurcation. Part II: Application to Graft DesignIEEE Transactions on Biomedical Engineering, 2008
- Experimental validation of a time-domain-based wave propagation model of blood flow in viscoelastic vesselsJournal of Biomechanics, 2008
- Pulse wave propagation in a model human arterial network: Assessment of 1-D numerical simulations against in vitro measurementsJournal of Biomechanics, 2007
- Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flowsJournal of Biomechanics, 2007
- In vivo validation of a one-dimensional finite-element method for predicting blood flow in cardiovascular bypass graftsIEEE Transactions on Biomedical Engineering, 2003
- Numerical Simulation and Experimental Validation of Blood Flow in Arteries with Structured-Tree Outflow ConditionsAnnals of Biomedical Engineering, 2000