Safety Measurements for Heating of Instruments for Cardiovascular Interventions in Magnetic Particle Imaging (MPI) ‐ First Experiences
Open Access
- 1 January 2014
- journal article
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 5 (1) , 79-94
Abstract
Magnetic particle imaging (MPI) has emerged as a new imaging method with the potential of delivering images of high spatial and temporal resolutions and free of ionizing radiation. Recent studies demonstrated the feasibility of differentiation between signal‐generating and non‐signal‐generating devices in Magnetic Particle Spectroscopy (MPS) and visualization of commercially available catheters and guide‐wires in MPI itself. Thus, MPI seems to be a promising imaging tool for cardiovascular interventions. Several commercially available catheters and guide‐wires were tested in this study regarding heating. Heating behavior was correlated to the spectra generated by the devices and measured by the MPI. The results indicate that each instrument should be tested separately due to the wide spectrum of measured temperature changes of signal‐generating instruments, which is up to 85°C in contrast to non‐signal‐generating devices. Development of higher temperatures seems to be a limitation for the use of these devices in cardiovascular interventions.Keywords
Funding Information
- Bundesministerium für Forschung, Technologie und Raumfahrt (13N11090)
This publication has 25 references indexed in Scilit:
- Emerging technologies for image guidance and device navigation in interventional radiologyMedical Physics, 2012
- RF Heating of MRI-Assisted Catheter Steering Coils for Interventional MRIAcademic Radiology, 2011
- Intraprocedural imaging: Flat panel detectors, rotational angiography, FluoroCT, IVUS, or still the portable C-arm?Journal of Vascular Surgery, 2010
- MR imaging during endovascular procedures: An evaluation of the potential for catheter heatingMagnetic Resonance in Medicine, 2008
- Three-Dimensional C-arm Cone-beam CT: Applications in the Interventional SuiteJournal of Vascular and Interventional Radiology, 2008
- MR‐guided intravascular interventions: Techniques and applicationsJournal of Magnetic Resonance Imaging, 2008
- Heating of metallic implants and instruments induced by gradient switching in a 1.5‐Tesla whole‐body unitJournal of Magnetic Resonance Imaging, 2007
- Dependence of RF Heating on SAR and Implant Position in a 1.5T MR SystemMagnetic Resonance in Medical Sciences, 2007
- MR Image–guided Endovascular Procedures with the Ultrasmall Superparamagnetic Iron Oxide SH U 555 C as an Intravascular Contrast Agent: Study in PigsRadiology, 2003