Comparison of two magnetic resonance imaging spectroscopy postprocessing methods
Open Access
- 1 November 2021
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Revista da Associação Médica Brasileira
- Vol. 67 (11) , 1616-1621
Abstract
OBJECTIVE: The aim of this study was to compare the results obtained using SpectroView (R) (SV) and J-Magnetic Resonance User Interface (jMRUI) from the same magnetic resonance (MR) spectroscopy of hydrogen data. METHODS: Data from 23 males with alcohol use disorder (AUD) and 23 healthy non-AUD males were acquired by a 1.5 Tesla MR using a PRESS sequence (TE=30 ms) in four voxels located in the right frontal and left frontal (RF and LF) lobes, and posterior cingulate (AC and PC). The ratio of the signals from both N-acetyl-aspartate (NAA) and choline (Cho) over creatine (Cr) was calculated automatically using SV and semiautomatically by an expert neuroradiologist using jMRUI. The software' agreement was calculated by the 95% limits of agreement (LoA) of the ratio of the obtained values. RESULTS: The standard deviation was greater in jMRUI than in SV. Although there was a correlation between the results from both methods, it was not possible to predict their variance from one another. Additionally, the 95% LoA showed that jMRUI values were expected to vary from 38 to 190% of those obtained using SV for NAA/Cr in RF of AUD subjects and from 48 to 196% for NAA/Cr in CONCLUSIONS: The difference between the methods may represent clinically significant magnitudes. We suggest the use of the same method when comparing spectroscopic data. We also suggest that in clinical practice, the automatic method should be preferred.Keywords
This publication has 15 references indexed in Scilit:
- Brain proton magnetic resonance spectroscopy of alcohol use disorders2014
- Proton Magnetic Resonance SpectroscopyNeuroimaging Clinics Of North America, 2013
- Brain Proton Magnetic Resonance SpectroscopyNeuroimaging Clinics Of North America, 2013
- MR Spectroscopy and Spectroscopic Imaging of the Brain2010
- Quantitation of magnetic resonance spectroscopy signals: the jMRUI software packageMeasurement Science and Technology, 2009
- Computation of brain metabolite ratios in single-voxel proton MR spectroscopy: comparison between semiautomatic and automatic softwareLa radiologia medica, 2009
- An Introduction to the Fourier Transform: Relationship to MRIAmerican Journal of Roentgenology, 2008
- Alcohol consumption significantly influences the MR signal of frontal choline-containing compoundsNeuroImage, 2006
- Proton magnetic resonance spectroscopy in the brain: Report of AAPM MR Task Group #9Medical Physics, 2002
- Improved Method for Accurate and Efficient Quantification of MRS Data with Use of Prior KnowledgeJournal of Magnetic Resonance, 1997