A Combined Fuzzy C-Means and Level Set Method for Automatic DCE-MRI Kidney Segmentation Using Both Population-Based and Patient-Specific Shape Statistics
Authors:
- 1 July 2020
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Abstract
Kidney segmentation from Dynamic Contrast Enhanced Magnetic Resonance Images (DCE-MRI) is a fundamental step for the early detection of transplanted kidney function. This paper presents an accurate and automatic DCE-MRI kidney segmentation method which combines fuzzy c-means (FCM) algorithm and geometric deformable model (level set) method. In order to precisely extract the kidney from its background, the evolution of the level set contour in the proposed method is controlled by the fuzzy memberships of the pixels and both population-based and patient-specific shape model. The FCM algorithm is used to initially divide the input image into kidney and background clusters. The obtained fuzzy clustering membership is used to define the initial contour of the level set method. For segmenting the kidney of a specific patient, a number of high contrast time-point images are segmented constraining the evolution of the level set contour by the population-based shape model constructed from different subjects. As more images are segmented, the patient-specific shape model is built from the obtained segmentation results and gradually used to guide the evolution of the level set contour. The performance of the proposed method is evaluated on 40 subjects. Experimental results demonstrate the efficiency, consistency, and accuracy of the proposed method especially for low contrast images.Keywords
This publication has 19 references indexed in Scilit:
- Geometric Deformable Models2015
- Segmentation-Driven Image Registration-Application to 4D DCE-MRI Recordings of the Moving KidneysIEEE Transactions on Image Processing, 2014
- Dynamic Contrast-Enhanced MRI-Based Early Detection of Acute Renal Transplant RejectionIEEE Transactions on Medical Imaging, 2013
- Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A surveyAIP Conference Proceedings, 2013
- Non-invasive Image-Based Approach for Early Detection of Acute Renal Rejection2010
- A Kidney Segmentation Framework for Dynamic Contrast Enhanced Magnetic Resonance ImagingJournal of Vibration and Control, 2007
- A New CAD System for the Evaluation of Kidney Diseases Using DCE-MRI2006
- Statistical validation of image segmentation quality based on a spatial overlap index1Academic Radiology, 2004
- A shape-based approach to the segmentation of medical imagery using level setsIEEE Transactions on Medical Imaging, 2003
- Active Shape Models-Their Training and ApplicationComputer Vision and Image Understanding, 1995